Komatsu D32E-1 Operation & Maintenance Manual page 54

Bulldozer
Hide thumbs Also See for D32E-1:
Table of Contents

Advertisement

12. OPERATION
121.2
CHECK BEFORE STARTING
12.1.2.1 CHECK AND REFILL COOLANT
1. Check the coolant level in radiator sight glass to make sure coolant is
present.
Do not remove cap while coolant is hot. Hot coolant may spout out.
"
WARN'NG
'p
When removing cap wait until the coolant
temperature
goes down
then remove the cap:
and release radiator pressure little by little by loosening caps slowly,
2. Open the hood door at the front of the machine.
3. Remove the radiator cap and check that the coolant level is visible. If
level is low, add coolant until it is visible in sight gauge.
REMARK
For details of the coolant to use, see 20. USE OF FUEL, COOLANT AND
LUBRICANTS
ACCORDING
TO AMBIENT TEMPERATURE.
4. After adding coolant, tighten the cap securely.
12.1.2.2 CHECK FUEL LEVEL
I
A
WARN'NG
1
When addmg fuel, never let the fuel overflow. Thus may cause a fire.
If spilling fuel, thoroughly
clean up any spillage.
1. Check the fuel level using fuel gauge.
2. After completing work, fill the fuel tank through the filler port .
REMARK
For details of the fuel to use, see 20. USE OF FUEL, COOLANT AND
LUBRICANTS
ACCORDING
TO AMBIENT TEMPERATURE.
3. After adding fuel, tighten the cap securely.
REMARK
Fuel capacity: 146 @ (38.5 gal)
2-21