24. SERVICE
PROCEDURE
24.3.3 CHECK EQUIPMENT SYSTEM HYDRAULIC OIL LEVEL
1.
2.
3.
4.
+
With the oil at operating or ambient temperature,
park the machine on
level ground, lower the blade to the ground, release the control lever and
stop the engine.
Check oil level at sight gauge on the side of the reservoir. Add oil if level
is below the center line of the gauge.
Slowly loosen the reservoir fill cap to relieve any reservoir pressure, then
remove cap.
Add fluid to the reservoir to bring the level up to the center line of the sight
gauge. Replace reservoir filler cap.
For details of the fluid to use, see 20. USE OF FUEL, COOLANT AND
LUBRICANTS
ACCORDING
TO AMBIENT TEMPERATURE.
24.3.4
FILL FUEL TANK
When adding fuel, never allow the fuel to over flow. This may cause a
A
WARNlNG
1
fire. If fuel is spilt, thoroughly
clean up any spillage.
1.
2.
3.
Check the fuel level using the fuel gauge.
After completing work, fill the fuel tank through the filler port
REMARK
For details of the fuel to use, see 20. USE OF FUEL, COOLANT AND
LUBRICANTS
ACCORDING
TO AMBIENT TEMPERATURE.
After adding fuel, tighten the cap securely.
REMARK
Fuel capacity: 146 Q (38.5 gal)