Crestron BB-6X-DSW Pre-Construction Wall Mount Back Box: BB-6X-DSW Description The Crestron enclosure for the TPS-6X-DSW Wall Mount Docking Station. Designed for pre- construction applications, the BB-6X-DSW permits fastening to the left or right side of a stud in a framed wall prior to installation of sheet rock. Conduit knockouts are provided on the top and bottom to accommodate a variety of fittings and a blank cover plate is included.
Page 6
Pre-Construction Wall Mount Back Box The mounted view of the BB-6X-DSW is shown in the following illustration. BB-6X-DSW Mounted View (Optional Cover Plate Attached) 2 • Pre-Construction Wall Mount Back Box: BB-6X-DSW Crestron BB-6X-DSW Installation Guide – DOC. 6728A...
Page 7
Crestron BB-6X-DSW The dimensions of the BB-6X-DSW are shown in the following illustration. BB-6X-DSW Overall Dimensions (Front View) 9.06 in (23.01 cm) (22.54 cm) 6 1/4 in 158 mm) Installation Guide – DOC. 6728A Pre-Construction Wall Mount Back Box 8.88 in 6.35 in (16.13 cm) 6 3/16 in...
Page 8
Pre-Construction Wall Mount Back Box BB-6X-DSW Overall Dimensions (Bottom View) NOTE: Knockout holes are intended for Class 2 wiring only and are ½” and ¾” diameter. BB-6X-DSW Overall Dimensions (Cover Plate) 4 • Pre-Construction Wall Mount Back Box: BB-6X-DSW 3.31 in (8.41 cm) 3.25 in (8.25 cm)
Crestron BB-6X-DSW Setup Assembly Required Tools: The back box mounting enclosure comes fully assembled except for a grounding screw. To prepare for mounting, complete the following procedure: NOTE: The #08-8B self-tapping screw (2007277), supplied for grounding purposes, is installed in the rear of the back box mounting enclosure assembly. Mounting Required Tools and Materials: CAUTION: Allow an air gap of a least 12 inches (30.48 cm) in the wall cavity...
Page 10
Pre-Construction Wall Mount Back Box Mounting the Back Box ENSURE THESE SURFACES ARE FLUSH SCREW (1) #08-8B x ¼" SELF-TAPPING FOR GROUNDING (2007277) 6 • Pre-Construction Wall Mount Back Box: BB-6X-DSW Crestron BB-6X-DSW BACK BOX MOUNTING ENCLOSURE ASSEMBLY (4507462) NOTE: BE SURE THE ASSEMBLY IS LEVEL WHEN MOUNTED.
Crestron BB-6X-DSW Mounted View with Cover Plate (Mounting Example Prior to Drywall Installation) SCREWS (4) #06-32 x 1½" PAN HEAD (2007254) NOTE: Cut the drywall to the inside edge of the front of the back box. The labels on the front of the back box indicate the perimeter of the opening that should be cut out.
Pre-Construction Wall Mount Back Box Mounting TPS-6X-DSW Docking Assembly and BB-6X-DSW Back Box – Exploded View DRYWALL TPS-6X-DSW SCREWS (4) #06-32 x 1½" PAN, PHIL (2007254) Other Mounting Option Accessories If too much of the mounting plate is exposed after the drywall is cut, you may need to patch the area.
Crestron BB-6X-DSW Resources Industry Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. As of the date of manufacture, the BB-6X-DSW has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.
Pre-Construction Wall Mount Back Box Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Page 15
Crestron BB-6X-DSW Pre-Construction Wall Mount Back Box This page is intentionally left blank. Pre-Construction Wall Mount Back Box: BB-6X-DSW • 11 Installation Guide – DOC. 6728A...
Page 16
Crestron Electronics, Inc. Installation Guide – DOC. 6728A 15 Volvo Drive Rockleigh, NJ 07647 (2021897) Tel: 888.CRESTRON 12.08 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.