Multisurface mount kit
Hide thumbs Also See for TSW-770 Series:

Advertisement

Quick Links

TSW-770/1070-MSMK-ANG
Multisurface Mount Kit for TSW-770 and TSW-1070 Series, Angled
The
TSW-770/1070-MSMK-ANG
versatile mounting solution for a TSW-770, TSS-770, TSW-1070, or
TSS-1070
touch screen. Using the kit, the touch screen can be mounted
directly to glass, granite, marble, wood paneling, plaster, smooth
masonry, or virtually any other flat surface. The touch screen can also be
mounted into a wall or supported electrical boxes. When installed, the
touch screen is angled upwards at a 20° tilt.
In the Box
1
TSW-770/1070-MSMK-ANG, Multisurface Mount Kit
Additional Items
2
Screw, 6-32 x 3/8 in., Phillips (2013475)
4
Screw, 6-32 x 1/2 in., Phillips (2007240)
2
Screw, 6-32 x 3/4 in., Phillips (2033247)
4
Screw, 6-32 x 1 in., Phillips (2007251)
4
Screw, M3 x 25 mm, Phillips (2049589)
2
Screw, M3.5 x 25 mm, Phillips (2049591)
4
Washer, #6 (2007663)
TSW-770/1070-MSMK-ANG-B-S Only
1
Bracket, Angle MSMK, with Adhesive, Black (4537884)
1
Faceplate, Front, Black (2056894)
1
Faceplate, Rear, Black (2056896)
1
Label, Polycarbonate, Black (4532843)
TSW-770/1070-MSMK-ANG-W-S Only
1
Bracket, Angle MSMK, with Adhesive, White (4537883)
multisurface mount kit provides a
1
Faceplate, Front, White (2056893)
1
Faceplate, Rear, White (2056895)
1
Label, Polycarbonate, White (4532842)
Install the MSMK
The TSW-770/1070-MSMK-ANG can be installed over an electrical box,
into drywall, or onto a flat, smooth surface. Procedures for each
installation are provided in the sections that follow.
Electrical Box Mounting
NOTE: For U.S.-style installations, use a #2 Phillips screwdriver. For
European and U.K.-style installations, use a #1 Phillips screwdriver or
equivalent.
1. Route all necessary cables through the rear of the electrical box.
2. Attach the rear faceplate to the wall:
NOTE: Ensure that the rear faceplate is oriented so that the
"TOP" machined text is facing upward prior to installation. Also
ensure that the faceplate is level after installation.
For U.S.-style installations, use the four provided 6-32 x 1 in.
l
screws to install the rear faceplate over a 2-gang, or 3-gang
U.S. electrical box (as shown in the following illustration).
For European-style installations, use the four provided
l
M3 x 25 mm screws to install the rear faceplate over a 2-gang
European electrical box.
Quick Start
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the TSW-770 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Crestron TSW-770 Series

  • Page 1 Quick Start TSW-770/1070-MSMK-ANG Multisurface Mount Kit for TSW-770 and TSW-1070 Series, Angled TSW-770/1070-MSMK-ANG multisurface mount kit provides a Faceplate, Front, White (2056893) versatile mounting solution for a TSW-770, TSS-770, TSW-1070, or Faceplate, Rear, White (2056895) TSS-1070 touch screen. Using the kit, the touch screen can be mounted Label, Polycarbonate, White (4532842) directly to glass, granite, marble, wood paneling, plaster, smooth masonry, or virtually any other flat surface.
  • Page 2 Quick Start TSW-770/1070-MSMK-ANG Multisurface Mount Kit for TSW-770 and TSW-1070 Series, Angled For U.K.-style installations, use the two provided M3.5 x 25 mm 3. Press the front faceplate into the rear faceplate until it snaps into screws to install the rear faceplate over a 2-gang U.K. electrical place.
  • Page 3 Quick Start TSW-770/1070-MSMK-ANG Multisurface Mount Kit for TSW-770 and TSW-1070 Series, Angled 4. Attach the angled bracket to the front faceplate using the four NOTE: If the front faceplate needs to be removed, insert the tip provided 6-32 x 1/2 in. screws. of a flathead screwdriver (or similar tool) into the machined notches on the bottom of the faceplate, and then carefully push against the faceplate to pop it off.
  • Page 4: Drywall Mounting

    Quick Start TSW-770/1070-MSMK-ANG Multisurface Mount Kit for TSW-770 and TSW-1070 Series, Angled Drywall Mounting 5. Attach the TSW-770/1070 mounting bracket (provided with the touch screen) to the angled bracket using the two provided 6-32 x 3/8 in. screws. Ensure the bracket is level after installation. 1.
  • Page 5: Surface Mounting

    Quick Start TSW-770/1070-MSMK-ANG Multisurface Mount Kit for TSW-770 and TSW-1070 Series, Angled Surface Mounting Attach the Angled Bracket to the Mounting Surface Use the following procedures to mount the MSMK onto a flat pane of 1. Select a mounting location for the MSMK and determine whether glass or a similar smooth surface (such as granite, marble, plaster, or raceway (not included) will be entering the MSMK from the top, smooth stone and masonry).
  • Page 6 30 seconds to ensure the adhesive bonds to the surface. NOTE: To ensure the raceway fits into the knockout, Crestron recommends using raceway with the following NOTE: All air bubbles must be smoothed out and eliminated to dimensions: 0.45 H x 0.77 in.
  • Page 7 4. Hold the label at a 45-degree angle to the angled bracket, and then align the lower edge of the label with the lower edge of the bracket. Scan the QR code to visit the product page. Do not allow the label adhesive to come in contact with the surface. TSW-770/1070-MSMK-ANG www.crestron.com/model/6511786...
  • Page 8 Development Tools License Agreement. Crestron product operating system software is licensed to Crestron dealers, CSPs, and end-users under a separate End-User License Agreement. Both of these Agreements can be found on the Crestron website at www.crestron.com/legal/software_license_agreement. The product warranty can be found at www.crestron.com/warranty.

This manual is also suitable for:

Tsw-1070 seriesTsw-770-msmk-angTsw-1070-msmk-ang