Skov DA 600 Technical User Manual

Wall exhaustion
Hide thumbs Also See for DA 600:

Advertisement

Quick Links

DA 600 Wall Exhaustion
Technical User's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DA 600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Skov DA 600

  • Page 1 DA 600 Wall Exhaustion Technical User's Guide...
  • Page 2 Mounting of Air Direction Baffle..................5 2.2.5 Attachment of Wall Exhaustion..................5 2.2.6 Mounting of Guard Net ....................5 INSTALLATION GUIDE MAINTENANCE INSTRUCTIONS DA 600 Wall Exhaustion ..................6 Guard Net ......................6 Fan ........................6 TROUBLE SHOOTING INSTRUCTIONS DA 74 ........................6 Fan ........................6 SPARE PARTS...
  • Page 3 Technical User's Guide 1 Product Description The wall exhaustion from SKOV A/S is used for air outlet from livestock houses through exhaust units located in the wall. The wall exhaustion comprises DA 600 wall exhaustion with fans and swivel shutters.
  • Page 4 Technical User's Guide Roof duct Swivelshutter Bell mount Figure 2: Principle drawing of DA 600 wall exhaustion 2.2.1 Assembly and Adjustment of the Duct Parts Assembly of duct: • Assemble each duct by pressing lightly after which a labyrinth/bayonet joint engages. Let go of the duct which has now been assembled.
  • Page 5 2.2.4 Mounting of Air Direction Baffle Is only done in stepless DA 600 units. See Instruction for Mounting of air direction baffle (603690). 2.2.5 Attachment of Wall Exhaustion • Fasten the wall exhaustion, e.g. with eight screws from the inside and adjust the distance pieces between duct and wall.
  • Page 6 Technical User's Guide 3 Installation Guide For installation of DA 600 wall exhaustion please refer to the wiring diagrams in Instruction for DA 74A winch motor (603701). Installation of fan Lay the cable from the motor through the wall with the duct and assemble in DA 74 winch motor.
  • Page 7 Inside diameter bell mouth: 6,500 mm As regards data concerning fans, please refer to the Technical Info Fans (item number 604060). For any further information concerning DA 600 wall exhaustion, please refer to Techncial Information: Exhaust unit DA 600 (item number 602331).
  • Page 8 SKOV A/S • Hedelund 4 • Glyngøre • DK-7870 Roslev Tel. +45 72 17 55 55 • Fax +45 72 17 59 59 • www.skov.com • E-mail: skov@skov.dk...

Table of Contents

Save PDF