Troubleshooting
8.3 Load a firmware file via TFTP.
6. Assign an IP address to the device using DHCP or SINEC PNI.
7. In a Windows command prompt, go to the directory where the file with the new firmware is
located and use the following command:
tftp -i <IP address> put <firmware file>.
Note
You can enable TFTP in Microsoft Windows as follows:
"Control Panel" > "Programs and Features" > "Turn Windows features on or off" > "TFTP Client".
Once the firmware has been transferred completely to the device and validated, the device
restarts. This may take a few minutes.