Description of the device
4.2 Device views
4.2.4
SCALANCE XR522-12 100 ... 240 V AC / 110 ... 250 V DC
The following figure shows an overview of the components of a 100 to 240 V AC / 110 to
250 V DC device version of the SCALANCE XR522-12.
①
Electrical ports with 10/100/1000 Mbps
②
Slots for SFP plug-in transceiver with 100/1000 Mbps
③
Slots for SFP/SFP+ plug-in transceiver with 1/10 Gbps
④
Electrical ports with 1/2.5/5/10 Gbps
⑤
Mounting brackets for 19" rack installation
⑥
Connection to the 100 to 240 V AC power supply
Single or redundant design depending on the device version. The figure shows the device with a redundant connec‐
tion.
⑦
Connection to the 110 to 250 VDC power supply (hidden behind a screw-retained cover)
Single or redundant design depending on the device version. The figure shows the device with a redundant connec‐
tion.
⑧
Grounding bolt for connection of protective grounding
⑨
Signaling contact
⑩
USB console interface (2.0 port, Type B, serial via USB)
⑪
CLP slot with an inserted CLP
⑫
"SELECT/SET" button
⑬
LED display
•
Port LEDs
•
"F" LED for the fault display
•
"L1/L2" LED for the power supply
•
"RM" LED for the redundancy manager function
•
"SB" LED for the status of the standby function
•
"DM1/DM2" LED for the display mode
Figure 4-4
SCALANCE XR522-12 100 ... 240 V AC / 110 ... 250 V DC, front and rear
30
Operating Instructions, 07/2023, C79000-G8976-C692-01