CONTROL BUTTONS
•
Press to access/exit INRUSH mode
•
Long press to open/close the data logger (REC); use the Start/
Stop button
•
Press to step through the ranges manually
•
Long press while in manual range mode to return to Auto range
mode
•
Long press to Send data logs via Bluetooth (refer to User Manual
for complete instructions)
•
Press to access the Data Hold mode
•
Long press to activate/deactivate Bluetooth
•
While in data log mode, press to Start/Stop recording
•
Long press to switch power ON/OFF
•
When powered, press to switch worklights ON/OFF
DISPLAY ICONS
Bluetooth
Battery
status
Bulk data
%
transmit
AC CURRENT MEASUREMENTS
WARNING
Ensure that power to the device under test is OFF before starting this proce-
dure. Switch power to the device under test ON only after the clamp has been
safely attached.
WARNING
Do not move your fingers above the LCD at any time during a test.
#NAS100141; r. AA/89762/89785; en-GB
to control the data logger
Display Hold
Inrush
current
Recording
mode
Amperes
Auto power off
Auto range