FAN AND THERMODISC

The 115 volt fan must be screwed under the ventilation conduct at the back of the
appliance. The controller for the furnace must be installed on the support at the top of
the furnace. The rod of the controller must pass through the 1 inch hole of the support
and the plenum.
When the appliance is in function, the heat reaching at 120 °F activates the controller to
distribute the heat in your home. As soon as the heat goes under 70 °F, the controller
automatically stops the fans.
When both the appliance and the controller are on and the temperature reaches
at 200 °F, the controller will close the air entry without stopping the fan in order to slow
down the combustion and will continue the distribution of the heat in the ventilation
conduct of your home to prevent the furnace from overheating. When the heat goes
under 200 °F, the controller will automatically allow to reopen the air inlet.
The electrical cord of the furnace must never touch the appliance