Combustion Air Supply; In Case Of A Glass Replacement - J. A. Roby ULTF Instruction Manual

Table of Contents

Advertisement

A new combustion air supply can be done by either of following ways:
Indirect method:
Ventilation system:

IN CASE OF A GLASS REPLACEMENT

Remove the screws that retain the glasses and then, the fragments of glasses. Check if
the seal cords are damaged.
If so, replace them by a ½ inch ceramics cord and replace the broken glasses by
VITROCERAMICS glasses of 4mm.
Cut the glass edge 3mm smaller on each side, so that the fiberglass cord can be slipped
on the edge of the glass at the time of its installation. Fix the glass by screwing it.
Contact your retailer to obtain any information you might need for the replacement of the
glasses.
PR_I019/2020-11-16-EN

COMBUSTION AIR SUPPLY

In the case of an appliance not certified for a direct connection
with a source of new air supply, the new air is brought in a duct
at a maximum of 300 mm (12 in) of the appliance, in order not to
compromise its operation.
If the home is built with a ventilation system (air exchange or
heat recovery)
i.
The ventilation system might be able to supply an
efficient air quantity with a solid combustible appliance,
and
ii.
The owner should be informed if the ventilation system
might have to be rebalanced by a ventilation specialist
after the installation of the solid combustible appliance.
DO NOT USE SUBSTITUTES.
Revision: 5
29

Advertisement

Table of Contents