Fans And Thermodisc - J. A. Roby GRIZZLY Owner's Manual

Wood furnace
Table of Contents

Advertisement

The 115 volts fans must be screwed under the ventilation conduct at the planned place in
the appliance rear. The F120 thermodisc must be installed beside the junction box,
provided for this purpose.
When the appliance is in function, the heat reaching a temperature of
F120 thermodisc. At this moment, the fan is activated for a better distribution of heat in
your home.
When the appliance is in function, and that conduct reaches a temperature of 160
FS160 thermodisc will close the air entry without stopping the fan in order to slow down
the combustion and will continue the distribution of the heat in the ventilation conduct of
your home to prevent overheating in the conducts. When the heat goes under 160
FS160 thermodisc will automatically allow the air entry reopening.
The electrical cord of the furnace must never touch the appliance surfaces in order
to avoid electrical shock or fire.

FANS AND THERMODISC

ELECTRICAL PLAN
activates the
120° F
0
F, the
0
F, the
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grizzly furnace

Table of Contents