AIR CIRCULATION OF THE HEATING SYSTEM

Always refer to the applicable building code before installing the hot air conduct.
Hot air pipe:
An air supply must be installed if:
• The appliance seems to have an irregular draft control, a smoke return, a bad
combustion and a counterblow whether you have combustion or not.
• Your other appliances, such as hearths or other heating appliances, release
odors, provide poor performance, provoke smoke return or a counterblow
whether there is combustion or not.
• If the window is open, even slightly, in the calm weather (no wind), the situation
above is solved.
• Your home is built with vapour barrier and airtight windows, and/or with a system
device to blow the air outside.
In these circumstances, which mean the air infiltration is inefficient, you must ensure an
adequate air supply.
* In doubt, it is recommended to ensure an adequate supply of fresh air.
PR_I019/2020-11-16-EN
8" diameter for 20 feet length.
6" diameter for 15 feet length.
Revision: 5
It is recommended to install a
floor screen in order to balance
the air pressure between the
floor where the appliance is
installed and the superior floor.
It is also recommended to install
those floor screen to each home
extremity.