Vaisala HMP80 Series User Manual
Vaisala HMP80 Series User Manual

Vaisala HMP80 Series User Manual

Handheld humidity and temperature probes
Table of Contents

Advertisement

Quick Links

M212903EN-A
User Guide
Vaisala Handheld Humidity
and Temperature Probes
HMP80 Series

Advertisement

Table of Contents
loading

Summary of Contents for Vaisala HMP80 Series

  • Page 1 M212903EN-A User Guide Vaisala Handheld Humidity and Temperature Probes HMP80 Series...
  • Page 2 This product contains software developed disclosed to a third party without prior by Vaisala or third parties. Use of the written permission of the copyright holder. software is governed by license terms and Translated documents and translated...
  • Page 3: Table Of Contents

    Example of configuring filtering factor with Indigo80 handheld indicator.................. 23 Configuring environment settings with Indigo80 handheld indicator..24 Configuration with Insight software............. 26 Vaisala Insight PC software................26 Connecting to Insight software..............26 Configuration options..................27 Diagnostics in Insight..................27 Calibration and adjustment..............
  • Page 4 Performing manual adjustment with Indigo80 handheld indicator....................32 7.3.3 Restoring factory adjustment with Indigo80 handheld indicator..33 Adjusting measurement with Insight software.......... 34 HMK15 Humidity Calibrator with HMP80 series probes......35 Maintenance....................36 Cleaning the probe..................36 8.1.1 Chemical tolerance................. 36 Changing the probe filter................37 Troubleshooting....................
  • Page 5 Figure 16 HMP80L temperature measurement accuracy over full range... 43 Figure 17 Dimensions of HMP80L (top) and HMP80N (bottom), side and bottom view..................45 Figure 18 Vaisala Humidity Calculator in Advanced mode........47 Figure 19 Materials for recycling..................48...
  • Page 6 Table 8 HMP80 series inputs and outputs..............44 Table 9 HMP80 series output parameters..............44 Table 10 HMP80 series mechanical specifications............ 44 Table 11 HMP80 series compliance................45 Table 12 HMP80 series spare parts and accessories..........46 Table 13 Materials for recycling..................48...
  • Page 7: About This Document

    Chapter 1 – About this document 1. About this document 1.1 Version information This document provides instructions for using and maintaining Vaisala HMP80 HUMICAPâ Handheld Humidity and Temperature Probes. Table 1 Document versions (English) Document code Date Description M212903EN-A June 2023 First version.
  • Page 8: Trademarks

    M212903EN-A Note highlights important information on using the product. 1.4 Trademarks Vaisalaâ and HUMICAPâ are registered trademarks of Vaisala Oyj. Microsoftâ and Windowsâ are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. All other product or company names that may be mentioned in this publication are trade...
  • Page 9: Product Overview

    ‣ Indigo80 handheld indicator (page 18) ‣ Vaisala Insight PC software (page 26) 2.2 HMP80N and HMP80L probe models Both HMP80 series probe models have the same type of sensor, Vaisala HUMICAPâ R2C, with sensor purge and sensor warming functionality. Table 3 HMP80N and HMP80L temperature ranges...
  • Page 10: Output Parameters

    2.3 Output parameters Values of all available output parameters are locked (showing the latest valid value) when sensor purge or condensation prevention functions are active. Table 4 HMP80 series output parameters Output parameter name and unit Relative humidity (%RH) Absolute humidity (g/m...
  • Page 11: Probe Structure

    Detachable end piece of the probe handle, protecting the cable connector inside the handle â R2C sensor used in 1) The HUMICAP HMP80 series probes is not user- replaceable. To have the sensor replaced, contact a Vaisala Service Center.
  • Page 12: Safety

    2.6 ESD protection Electrostatic discharge (ESD) can damage electronic circuits. Vaisala products are adequately protected against ESD for their intended use. However, it is possible to damage the product by delivering electrostatic discharges when touching, removing, or inserting any objects in the equipment housing.
  • Page 13: Functional Description

    HMP80 series probes perform the purge at one day intervals (known as interval purge). If desired, sensor purge can also be performed when the probe is powered on (known as startup purge).
  • Page 14: Condensation Prevention Functions

    HMP80 Series User Guide M212903EN-A 3.3 Condensation prevention functions Condensation prevention prevents water from condensing on the sensor and interfering with humidity measurement. Use of condensation prevention is controlled by a single setting that can be changed with the Insight software or the Indigo80 handheld indicator.
  • Page 15: Filtering Factor

    Chapter 3 – Functional description Temperature compensation You need to set an external source for the temperature compensation setpoint if the sensor warming feature of the condensation prevention function prevents the probe's own temperature measurement, and the output parameters that require temperature information to be known are required.
  • Page 16: Attaching Cable To Probe

    HMP80 Series User Guide M212903EN-A 4. Attaching cable to probe • Probe connection cable (Vaisala item code 272075SP) The handle of HMP80 probes has a detachable end piece that protects the probe's cable connector from mechanical stress, such as physical shocks.
  • Page 17 Chapter 4 – Attaching cable to probe The probe is delivered with a yellow cap protecting the filter. Leave the protection cap on during storage, but remove it before taking the probe into use.
  • Page 18: Using Probe With Indigo80 Handheld Indicator

    5. Using probe with Indigo80 handheld indicator 5.1 Indigo80 handheld indicator Figure 4 Indigo80 handheld indicator Vaisala Indigo80 Handheld Indicator is a portable diagnostics tool that accommodates up to two Vaisala Indigo-compatible probes or transmitters for measuring a wide range of parameters. With the indicator, you can: •...
  • Page 19: Indigo80 Keypad

    5.2 Connecting probes to Indigo80 • Probe connection cable Up to two Vaisala Indigo-compatible probes or transmitters can be connected to the ports located on the bottom of Indigo80. You can connect and disconnect devices both when the indicator is powered on and when it is off.
  • Page 20: Figure 7 Connecting Probes To Indigo80

    HMP80 Series User Guide M212903EN-A Vaisala recommends using cables provided by Vaisala when connecting devices to the indicator. Cables and other accessories are available to order at store.vaisala.com. Figure 7 Connecting probes to Indigo80 M12-5F ports on the bottom of Indigo80 for connecting compatible Vaisala devices.
  • Page 21: Measurement Location

    Chapter 5 – Using probe with Indigo80 handheld indicator 2. Insert the probe connection cable in one of the ports on the bottom of the indicator. • Note the orientation of the cable connector when inserting it • Hold the connector in place while turning its locking ring clockwise – never twist the connector body! 3.
  • Page 22: Configuring Environmental Compensations

    HMP80 Series User Guide M212903EN-A Figure 8 Example installation Mount the probe head horizontally to prevent any water condensing on the probe head from running to the sensors Attach Indigo80 to a metallic surface using the optional magnetic hanger accessory (Vaisala item code ASM214318SP).
  • Page 23: Example Of Configuring Filtering Factor With Indigo80 Handheld Indicator

    Chapter 5 – Using probe with Indigo80 handheld indicator Accessing certain configuration options for your probe requires using the free Insight PC software, downloadable at www.vaisala.com/insight. 1. Connect the probe(s) to the indicator. 2. Open the main menu by pressing 3.
  • Page 24: Configuring Environment Settings With Indigo80 Handheld Indicator

    HMP80 Series User Guide M212903EN-A 5.5 Configuring environment settings with Indigo80 handheld indicator • Probe connection cable For optimal measurement accuracy, you can use the Indigo80 handheld indicator to give additional information about the connected probe’s measurement environment. The environment settings available via Indigo80 correspond to the environmental compensation settings of the probe.
  • Page 25 Chapter 5 – Using probe with Indigo80 handheld indicator 5. Select a setting from the list, for example, Pressure. a. Select the unit, if prompted. b. Use the arrow buttons to set the desired value, and then select OK or Set. You can also select to read the value from another probe connected to the indicator, provided that the probe can output the required compensation parameter.
  • Page 26: Configuration With Insight Software

    M212903EN-A 6. Configuration with Insight software 6.1 Vaisala Insight PC software Vaisala Insight PC software is a configuration software for Indigo-compatible probes and other supported devices. Insight is available for Microsoft Windowsâ operating systems (64-bit only). With the Insight software, you can: •...
  • Page 27: Configuration Options

    > Configure device to access the configuration options. If Insight has been set to Advanced mode, additional configuration options may be available. Use Advanced mode only when instructed to do so by product documentation or Vaisala technical support. Figure 9 HMP80L in Insight software More information ‣...
  • Page 28: Figure 10 Hmp80L Diagnostics In Insight (Advanced Mode)

    HMP80 Series User Guide M212903EN-A The files are in comma separated value (CSV) format. They can be opened for viewing in spreadsheet programs such as Microsoft Excel or in text editors. Figure 10 HMP80L diagnostics in Insight (advanced mode)
  • Page 29: Calibration And Adjustment

    Vaisala recommends sending the probe regularly to Vaisala for factory calibration. The probe is calibrated and adjusted at multiple points along its measurement range. Factory calibration always includes a traceable calibration certificate and adjustment, if needed.
  • Page 30: Calibration And Adjustment With Indigo80 Handheld Indicator

    Make sure that the measurement has stabilized and the reference environment is reliable. If the required adjustment is still too large, the probe needs to be serviced by Vaisala. When adjustment of humidity measurement is necessary, Vaisala recommends adjusting in two points, 11 %RH and 75 %RH.
  • Page 31: Performing Guided Calibration With Indigo80 Handheld Indicator

    You can choose to do either 1-point or 2-point calibration, and choose to use the reference environment or instrument of your choice, for example, another probe connected to your indicator. For relative humidity, you can choose to use Vaisala HMK15 Humidity Calibrator. For more information on HMK15, see HMK15 User Guide (M210185EN).
  • Page 32: Performing Manual Adjustment With Indigo80 Handheld Indicator

    HMP80 Series User Guide M212903EN-A 7.3.2 Performing manual adjustment with Indigo80 handheld indicator • Probe connection cable • Reference environment(s) for producing the desired reference values This procedure tells you how to use the indicator to adjust the probe's measurement in 1 ... 2 points.
  • Page 33: Restoring Factory Adjustment With Indigo80 Handheld Indicator

    Chapter 7 – Calibration and adjustment 10. In <parameter> adjustment view, check the difference between each reference and measured value. Very large differences may be due to insufficient stabilization time or unsuitable calibration setup. • To store the adjustments to the probe, scroll down and select Activate adjustment > OK.
  • Page 34: Adjusting Measurement With Insight Software

    HMP80 Series User Guide M212903EN-A 7.4 Adjusting measurement with Insight software • Computer with a Microsoft Windowsâ operating system (64-bit version) and Vaisala Insight PC software installed • Indigo USB adapter (item code USB2) or USB connection cable (item code 242659) •...
  • Page 35: Hmk15 Humidity Calibrator With Hmp80 Series Probes

    Sensors on the probe head are vulnerable to damage when the filter is removed. Handle the probe carefully and avoid touching the sensors. Vaisala HMK15 Humidity Calibrator is a suitable humidity reference for HMP80 series probes. When preparing the salt solutions and using the calibrator, follow the general instructions in HMK15 User Guide (M210185EN) to avoid common sources of calibration error.
  • Page 36: Maintenance

    HMP80 Series User Guide M212903EN-A 8. Maintenance 8.1 Cleaning the probe CAUTION! Do not attempt to clean the sensors under the filter. Do not spray anything directly on the probe head, since that may deposit impurities on the sensors. You can clean the probe, probe handle, and cable by wiping them with a soft, lint-free cloth moistened with water or a suitable cleaning agent, such as isopropyl alcohol.
  • Page 37: Changing The Probe Filter

    Chapter 8 – Maintenance 8.2 Changing the probe filter • New compatible filter • Clean lint-free gloves CAUTION! Sensors are easily damaged when the filter is not in place. Handle the probe head carefully. 1. Put on clean gloves before touching the filter. 2.
  • Page 38: Troubleshooting

    HMP80 Series User Guide M212903EN-A 9. Troubleshooting 9.1 Problem situations Table 5 Troubleshooting table Problem Possible cause Solution Measurement output seems Installation location is not Verify the installation location incorrect representative of actual and relocate the probe if conditions you want to necessary.
  • Page 39 Humidity measurement error out. [45] If the sensors are damaged or Humidity sensor failure [46] missing and the error message(s) stay active, contact Vaisala to have the probe repaired. Capacitance reference error Hardware fault. Contact Vaisala technical [47] support. Sensor heater error [212]...
  • Page 40: Restoring Factory Default Settings With Insight Software

    HMP80 Series User Guide M212903EN-A Warnings Calibration has expired [353] This warning is displayed by Calibrate the probe and update the calibration reminder the calibration date functionality if the calibration information. interval has been exceeded. Software restart [679] The probe has automatically Check that supply voltage is restarted itself.
  • Page 41: Restoring Factory Default Settings With Indigo80 Handheld Indicator

    Chapter 9 – Troubleshooting 9.4 Restoring factory default settings with Indigo80 handheld indicator • Probe connection cable If needed, you can restore the probe back to its factory default settings using the Indigo80 handheld indicator. The user adjustment of the probe and the settings or log files of the indicator itself are not affected.
  • Page 42: Technical Data

    HMP80 Series User Guide M212903EN-A 10. Technical data 10.1 HMP80 specifications Table 6 HMP80 series measurement performance Property Description/Value Relative humidity Measurement range 0 … 100 %RH ±0.8 %RH (0 … 90 %RH) Accuracy at +23 °C (73.4 °F) ±0.5 %RH (0 … 40 %RH) Factory calibration uncertainty ±0.8 %RH (40 …...
  • Page 43: Figure 13 Hmp80N Humidity Measurement Accuracy As A Function Of Temperature

    Temperature [ ° Figure 15 HMP80L humidity measurement accuracy as a function of temperature Table 7 HMP80 series operating environment Property Description/Value Operating temperature of probe body −10 … +60 °C (−14 … +140 °F) Operating temperature of probe head HMP80N: −20 …...
  • Page 44: Table 8 Hmp80 Series Inputs And Outputs

    M212903EN-A Property Description/Value without cable IP55: Limited protection against dust. Protected from water jets from any direction. Consult Vaisala if other chemicals are present. Consider safety regulations with flammable gases. Table 8 HMP80 series inputs and outputs Property Description/Value Operating voltage 15 …...
  • Page 45: Dimensions

    Chapter 10 – Technical data Property Description/Value Filters HMP80N: Stainless steel (AISI 316L) HMP80L: Porous stainless steel (AISI 316L) With holes and without an additional filter membrane. Vaisala item code of filter: DRW255306SP. Vaisala item code: HM47280SP Table 11 HMP80 series compliance Property Description/Value...
  • Page 46: Spare Parts And Accessories

    ASM214606SP 10.4 Accuracy of calculated output parameters HMP80 series probes measure relative humidity and temperature, and calculate the other output parameters from those two parameters. Accuracy of the calculated parameters is derived from the accuracy of the original RH and T measurements.
  • Page 47: Figure 18 Vaisala Humidity Calculator In Advanced Mode

    Chapter 10 – Technical data Figure 18 Vaisala Humidity Calculator in Advanced mode...
  • Page 48: Appendix A: Recycling Instructions

    M212903EN-A Appendix A. Recycling instructions These recycling instructions guide you on the end-of-life treatment of this Vaisala product. As waste regulations and infrastructure vary in each country, these instructions only indicate the different components to be separated and common ways to handle them. Always follow local requirements when disposing of the product.
  • Page 49 Appendix A – Recycling instructions Part Material Recycling Probe shaft Stainless steel (AISI 316L) Metal waste Probe handle Polyamide (PA), glass reinforced Dispose of or recycle as and thermoplastic elastomer (TPE) plastic according to local waste management practices and regulations Electronics Polyamide (PA), glass reinforced Dispose of or recycle as...
  • Page 51: Maintenance And Calibration Services

    Maintenance and calibration services Vaisala offers comprehensive customer care throughout the life cycle of our measurement instruments and systems. Our factory services are provided worldwide with fast deliveries. For more information, see www.vaisala.com/ calibration. • Vaisala Online Store at store.vaisala.com is available for most countries.
  • Page 54 www. v aisala.com...

This manual is also suitable for:

Hmp80nHmp80l