RECEIVING
The equipment has been put through severe
tests at the factory before shipped .
After un-
packing, however, check and see the following .
" Its nameplate data meets your requirements .
" It has sustained no damage while in transit .
" Fastening bolts and screws are not loosened .
" Devices built in the cabinet are not damaged
or missing .
STORAGE
If the equipment is temporarily stored or machine
stops for an extended length of time, the following
precautions should be taken .
LOCATION
Store the equipment under the following condi-
tions.
" Free from rainfall and drops of water
" Clean and dry
" Free from corrosive gas and liquid
" Ambient temperature :
-100 C to 400 C
" Less vibration
INSTALLATION
Select a location described in STORAGE and in-
stall the equipment by proper procedure in keep-
ing the equipment in good working condition .
WIRING
Make connections in reference to the interconnection
diagram furnished on your order and the follow-
ing .
COMPONENT ARRANGEMENT IN
VS-505Z11
Figs . 2 to 4 show component arrangement in the
VS-505Z]l
TERMINAL SIZES AND CARRYING
CURRENTS
Table 1 shows the size and the current carrying
capacities of the terminals of VS-505ZII .
Select
leads with sufficient current carrying capacity .
Refer to Cautibns when Wiring .
Table 1
Terminal Size and Current Capacity
Note :
1.'l'erminal size other than listed above is M4 and
current capacity is 2A or below.
2,l1ule of thumb of AC main circuit power capacity
12 x/
X
E x 1 (VA)
E: Supply voltage
is
AC main circuit current
INTERCONNECTIONS
Make connections of VS-505ZII with associate
units according to the interconnection diagram
separately furnished .
CAUTIONS WHEN WIRING
Main Circuits
Use 600 V PVC insulated wires or cabtyre cables
with the current carrying capacities of the com-
bined DC motor for AC main circuit terminals
(U, V, W) and DC main circuit terminals (P, 1) .
Field Circuits
Use 600 V PVC insulated wires or cabtyre cables
with the current carrying capacities of the com-
bined DC motor for field power circuit terminals
(Uo . Wo . U1, W1)
and field circuit terminals (J,
K) .
Use stranded wires of cross-section 5 .5 mmz
or larger for field circuit terminals (J, K) .
Signal Circuits
Use shielded wires or twisted wires of twisting
pitches 20 mm or smaller for the speed setting
circuit terminals (11 to 16), speed feedback ter-
minals (3 to 5), tachometer circuit terminals (38
to 40) .
D
-_
Fig . 1
Pitch of Twisted Wire
I
20 MM
MAX.
AC Main
DC Main
Field
C Dh1R-Z11
Circuit
Circuit
Circuit
Rated Rated
Car-
Car-
I
Car-
Volt-
Out-
Ter
-
rying
Ter-
rying
Ter-
rying
minal
Cur-
minal
Cur-
minal
Cur-
age
put
Size
rent
Size
rent
Size
rent
V
kW
A
A
A
25
M6
21
M5
25
35
M6
_
29
_M8
i
~_ -
35-
45
M6
`
37M8
45
104
i
1-'
90
M8
74
M8
90
230
105
M8_
86
M8
105
-
180
M10
147
M10
180
22
260
M10
213
M10
260
M4
420
M12
343
-
M12
420
M4
25
550
M12
-
449
M12
550
50
M8
41
M8
50
90
M8
74
M8
90
M4
12
105
M8
86
M8
105
I
460
180
M10
147
M10
180
260
M10
213
M10
260
M4
22
420
M12
343
M12 _,
420
M4
'
25
550
M12
449
N112
I
550