Product description The SCIL-B splice closure in-line is a gel-sealed fiber optic splice closure designed for cable joint applications in the telecom outside plant network. The closure has maximum splicing capacity of 192 splices and is suitable for deployment in aerial, underground or direct buried environments.
Kit content 2.3.2 Tray kit –Tray 48 1. Splicing tray (Using Tray 48) 2. Fusion splice protectors 3. Transportation tube 4. Tie Wraps Installation conditions precautions The closures can be installed at temperature between -5°C and 40°C. Standard kit is listed below, alternative kits and accessories are available. Body and cover Follow the installation instruction steps to ensure the Splicing tray with splice holder...
Page 3
Cut the strength member on both sides at a distance Clean the cable sheath with the cleaning tissue of 50 mm from the cable window cut. Install the strength member into the holding lug and secure the lug to the cable attachment bracket with the bolt. Select the appropriate blocking rings according to the cable outer diameter.
Page 4
4.11 Mark the cable where blocking rings will be installed as 4.14 At the cable port where cable will be installed, install shown. Install the rings over the cable with the slit positioned two pieces of black tie wraps. under the cable. 4.15 Position the cable with the pre-installed cable sealing block into the cable port and insert the cable attachment bracket...
4.18 Install a cable plug (hole towards outside) in all unused Wrap the cable with gel strip. Verify with a flat tool. closure cable ports. Continue wrapping the strip smoothly till the area between the two blocking rings is filled with gel strip. Remove the block when cable OD>16mm.
Make sure the ring tree in the slot and secure the Fiber preparation cable. When using Tray 24 6.1.1 In case of a looped cable, coil the loops and store them in the space in front of the tower of the closure (loops can be stored around the tower as well).
6.1.5 Route the transportation tubes to the tray entrance. 6.2.2 Remove the loose tubes up to 100mm from the cable Always route the tubes around the tray tower before entering the jacket end。 tray. 6.2.3 Degrease the fiber bundle and slide the transportation tubes over the fibers with overlap 100mm 6.1.6 Secure the transportation tube at the splice tray...
6.2.7 Remove/Install tray 48 as following shows Splicing and fiber storage Position the SCIL-B close to the splicing machine in a convenient location and secure the closure. Slide the heat-shrinkable splice protection over one fiber and fuse fibers according to local recommendations and procedures.
In case of two or more trays, use tray wedge to keep Secure the trays by the Velcro. the upper trays in upward position during installation on lower tray. After use, the tray wedge can be stored on the tower underneath the installed trays.
Field mounting of the closure Termination on aerial cables. Use the special designed bracket to secure the closure onto the supporting wire of the aerial cable. Install the two pieces bracket facing with bowing outwards to interlock the aerial cable. Termination in manholes.