6.1.4) Changing the gas springs (Ref. to Fig. 15)
Replace the gas springs when required as follows:
– Release the wheel arm so the springs are ex-
tended position.
– Using a flat-blade screwdriver, lift the retention
collar at the end of the spring, pulling with force
at the same time to release the spring from its
locating pins.
– Fit the new spring on the same pins and press
with force until this is properly fitted in the original
position.
Note: the two springs differ from one another.
6.1.5) Maximum pressure valve (Ref. to Fig. 16)
The hydraulic pump features a maximum pressure
valve, factory set and sealed at 42 Mpa.
NEVER CHANGE THE MAXIMUM PRES-
SURE VALVE SETTING AS THIS MAY CAUSE
SERIOUS DAMAGE TO THE MACHINE.
To check correct valve setting, a special pressure
testing gauge is available (Ref. to § 8).
6.2) Routine maintenance of the engine
Checks and periodical assistance are indispensable to ensure smooth engine operation.
Refer to the "Honda user's manual" supplied with the machine, for the following operations:
– Oil change.
– Air filter assistance (see double-element type).
– Cleaning sediments from sump.
– Spark plug cleaning; recommended plugs BPR6ES (NGK) or W20EPR-U (DENSE).
– Minimum carburettor setting.
6.3) Long periods of inactivity
– Store the machine in a dry environment, and adequately protect it against accidental damage
and contamination.
– For information on the combustion engine, refer to the "HONDA user's manual".