4.3) Controls
(Ref. to Fig. 5)
After gripping the handlebar (08), the operator can easily access all the unit controls and, more
specifically:
– Accelerator control lever (04): changes engine rpm.
– Worklight ON/OFF switch (05): in case of night work or bad lighting, the clamping area can
be illuminated by these side mounted lamps.
– Stop/emergency button (06) in a very visible position and easy to operate to stop the unit
normally and in case of an emergency.
NOTE: when this button is pressed it remains in OFF position. To start the engine, the button
should be turned clockwise so that it lifts automatically into the ON position.
The engine will not start unless the red button (06) is lifted.
– Clamp control lever (07) with swinging movement, for operating the clamps:
- right side for inserting E clips, "INSERT" position
- left side for extracting E clips, "EXTRACT" position
– Brake release lever (45): for safety reasons, the machine is equipped with an automatic
braking device. This device is always engaged within the rear wheel.
By pressing handle (45), the brake is released enabling movement of the machine along the
rail.
04
FIG. 5 – CONTROLS
11
05
07
08
06
45

Advertisement