– Pull the control lever to the right in "INSERT" position to gradually move the teeth for-
wards with consequent insertion of both E clips (see Fig. 11b and 11c).
When performing the insertion operation, each clamp teeth (33) will move in opposite
directions.
FIG. 11b
NOTE: During clip insertion, the movement of the teeth may NOT be simultaneous because the two
clamps operate independently.
FIG. 11c
FIG. 11d
– After insertion, pull the control lever to "EXTRACT" position for teeth (33) reversal (see
Fig. 11d).
– Raise the machine and go onto the next E clips.
– Repeat the above operations.
15
33
33
NOTE:
movement of one of the
clamps is schematically shown
in the illustrations; the other
will have an identical and op-
posite movement.
33