TROUBLESHOOTING
When the starting cable is pulled, the engine fails to start:
Is the Stop/Emergency button (06) released? (see § 4.3).
Is there enough oil in the combustion engine?
– The engine features an oil alert system to prevent damage caused by too little oil. Before
the level drops below safe limits, the alarm system automatically stops the engine.
Refer to the "HONDA owner's manual" for the type of recommended oil and topping up.
THE HYDRAULIC OIL SUPPLIED WITH THE MACHINE IS INTENDED ONLY FOR USE IN THE
HYDRAULIC PUMP AND IS MUST NOT BE USED IN THE ENGINE.
Is the fuel stopcock open?
Is there fuel in the tank?
Is fuel reaching the carburettor?
– To check, loosen the carburettor drainage screw with fuel cock open and refer to the "HONDA
owner's manual" .
Is the spark plug producing a spark?
– Remove the plug cap, clean around the plug and remove the plug using the spanner provided.
– Fit the plug back in the cap.
– Move button (06) to ON.
– After earthing the side electrode, pull the starting cable and check to see whether the plug
produces a spark.
If the engine still fails to start, contact CEMBRE (see § 7).