6.1.2) Topping up the oil in the hydraulic pump (Ref. to Fig. 14a)
Periodically check the level of the oil in the hydraulic
pump. The oil should always be visible inside the
tank (03). If the level is low, top up with the specific
oil recommended:
– Unscrew the cap and add sufficient oil to fill the
tank; do not exceed the oil level.
– After topping up, tightly screw the cap back on.
Always use clean recommended oil, see § 1.
Do not use old or recycled oil.
Do not use hydraulic brake fluid.
6.1.3) Changing worklight bulbs (Ref. to Fig. 14b-d)
– Loosen the locking nut (Fig. 14b).
– Turn worklight upwards and remove the two
screws in the lens (Fig. 14c) using a screwdriver.
– Remove the faulty bulb and replace with another
having the same specifications: 12V - 21W
– Replace lens and tighten the two screws.
– Reset worklight to original position and tighten
the nut.
The light bulb power circuit is protected by a
fuse against overcurrents and short-circuits.
In case of a fault:
– Remove the 4 screws from the lid of the terminal
box (14) using a screwdriver.
– Pull out fuse carrier and open it (Fig. 14d).
– Replace faulty fuse with a new one with the same
specifications: 6,3A - 250V
– Push fuse carrier back, replace lid and tighten 4
screws.
14
fuse-carrier
FIG. 14d
03
FIG. 14a
FIG. 14b
light bulb
12V - 21W
FIG. 14c
22