Installing the Device
2.7.1 Installing/removing power supply modules
Hot plugging power supply modules
Power supply modules are hot pluggable. Hot plugging allows you to exchange
power supply modules that have different voltage ratings while the device is
powered by the redundant power supply module
Wiring from the power source to the power supply module must be redesigned
following any hot plug operation. When replacing an AC power supply module with
a DC power supply module, an additional redesign of the power module slot is also
required.
The device must be powered down before any redesign of the power supply module
wiring is conducted.
A system restart is required following any redesign of the power supply module
wiring.
Required tools/hardware
Torx T10 screwdriver
1.5 mm (1/16 in) Allen key
Removing a power supply module
To remove a power module, do the following:
Electrocution hazard – risk of serious personal injury or death
Make sure power to the device is turned off before servicing the power supply
terminal.
1.
24
NOTICE
Hardware
DANGER
Using a Torx T10 screwdriver, loosen the screws that secure the module to the
chassis until the module can be removed.