MBT1015 rev-C
Press
key to continue and the display will show: (Fig.39)
Check the battery ratings and enter it as described in steps 11 to 13 (page
19~20) and the results will show as an example below: (Fig. 40)
Fig.36 - Results shown [Recharge], it indicated that the battery has to be fully
charged first before repeating the test.
15.
Pressing the
menu screen (Fig.22).
7.0 Continue Test
When this item is selected, it will allow you to select any one of the four tests namely:
Battery test, Starter Test, Charging Test and Grounding Test:
Select Rating
CCA
SAE
DIN
JIS
IEC
EN
CA
Unknown
Fig.39
Battery: Recharge
Rating:
400 CCA
Measured:
220 CCA
Volts:
11.96 V
Int. R: 12.27 mOhm
Volts is low! Charge
and test again.
Exit to Menu
Fig.40
key at any moment will exit and return back to the main
User's Manual Version 18.08
-