Parameter settings

For the parameter settings, refer to the following.
MELSEC iQ-F FX5 High-Speed Counter Module User's Manual

Performance value

Module
FX5UJ CPU module
FX5U CPU module, FX5UC CPU module
*1 When the program capacity is set to 128K steps, the processing speed may be reduced.
*2 The labels in the standard area are used.

Error code

Error code
Description
100H
The setting of i_uCH (Target channel) is out of the range. The
target channel is not within the range of 1 to 2.
101H
A module error occurred before the execution command was
turned on.
103H
The execution command was turned on while the count permit
command of the specified channel was on.
109H
The operation mode is set to other than the rotation speed
measurement mode.
Error other than the
Error code on the module side
above
Processing time
1.02ms
*1*2
0.768ms
2.4 M+FX5-2HC_RotationSpeedMeasure (Rotation Speed Measurement)
Maximum scan time
0.923ms
0.676ms
Action
Execute the FB again after checking the setting.
Reset the module error, and then execute the FB again.
Turn off all the count permit commands for the specified channel
before executing the FB.
Execute the FB again after reviewing the operation mode setting.
Refer to the following manual.
MELSEC iQ-F FX5 High-Speed Counter Module User's Manual
2 HIGH-SPEED COUNTER MODULE FB
Number of scans
2 scans
2 scans
27
2