Sanuvox SANUVAIR S300 OZD Instruction Manual

Garbage room odor reduction unit

Advertisement

Quick Links

REGISTER
YOUR WARRANTY
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit
or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
1.
Installation and servicing of UV units or systems (in an
air conditioning system or not) can be hazardous. Only
trained and qualified service personnel should install,
repair or service equipment.
2.
Untrained personnel can perform basic maintenance
functions such as replacing lamp(s) and/or filter(s). All
other operations should be performed by trained service
personnel.
3.
The unit is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge.
CAUTION: Unit is not a toy. Keep away from
unsupervised children. Do not leave children unattended
with the unit.
4.
DO NOT hang onto the UV unit or system.
5.
Some UV units or systems could be heavy: Make sure
you have a minimum of 2 people to safely move or install
these UV units or systems, and make sure you adopt the
most ergonomic position possible (use UV unit or system
handles, if applicable).
CAUTION: Installing or maintaining heavy equipment,
especially overhead, can cause back pain or other injuries.
6.
When installing or servicing an overhead UV unit or system,
be careful not to fall off the stepladder. Furthermore, make
sure the UV unit or system latches are always in place to
prevent falling parts.
CAUTION: Some parts of some UV units and systems
may open suddenly if the UV unit or system is installed
high up without its locks.
7.
Units that are obviously damaged must not be operated.
Installation Date: _______________
Installer Contact Info.: _________________________________________
SANUVAIR
GARBAGE ROOM ODOR REDUCTION UNIT
Commercial Model

IMPORTANT SAFETY INSTRUCTIONS

NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.
8.
CAUTION: When working on the UV unit or system,
observe precautions on the literature, tags and labels
attached to the UV unit or system, and all other safety
precautions considered as best practices in the HVAC
industry, if applicable.
9.
When applicable, local regulation may comprise more
restrictive installation and/or certification requirements.
The aforementioned requirements prevail on those of this
document and the installer agree to conform to these at his
own expense.
10. Follow all the safety instructions outlined in this document
and respect all local and national codes applicable.
11. All UV units or systems contain a UV-C source. Damage to
the housing or unintended use of the UV unit or system may
result in harmful UV-C leaks. UV-C may, even in little doses,
cause harm to the eyes and skin.
12. Never expose eyes or skin to an operating UV lamp.
Therefore, before installing or performing maintenance
on the UV unit or system, TURN OFF AND DISCONNECT
the UV unit or system from all power sources (there
may be more than one switch to disconnect) and also
disconnect the HVAC system, is applicable.
CAUTION: Electrical shock may cause injuries or
possibly death. FIRST AID INSTRUCTIONS: If injured,
consult a doctor.
13. UV rays may damage certain types of filters (polymer or
plastic); please keep the UV unit or system light away from
shining directly on plastic.
Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.2
S300 OZD
®
14. When installing or performing maintenance on the UV unit
15. Just like conventional fluorescent lamps, UV lamps contain
15.1. Dispose of unit or system according to the specific
16. Use only specified SANUVOX branded replacement
17. Sanuvox UV units or systems are not waterproof. DO NOT
18. Use of this unit or system supplements, but does not
Installed by: _________________
Instruction Manual
or system, it is recommended to wear safety gloves. In
order to avoid reduced performance of lamp(s), do not
touch lamp glass without gloves.
a small quantity of mercury: if a lamp breaks, clean and
dispose of with care. UV lamps can be disposed/recycled
after use in the same way as any other fluorescent lamps.
Contact and follow the specific instructions of your local
and national authorities.
instructions and standards of your local and national
authorities.
UV lamps for your UV unit or system. Use of any other
lamps will void your warranty and can result in damage to
the UV unit or system.
INSTALL OUTDOORS OR IN WET LOCATION unless
specified otherwise.
replace, infection control best practices. Users must follow
all these practices, particularly with regard to cleaning and
disinfecting surfaces.
SAVE THESE INSTRUCTIONS
For any inquiries on a UV unit or system, contact :
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
techsupport@sanuvox.com

Advertisement

Table of Contents
loading

Summary of Contents for Sanuvox SANUVAIR S300 OZD

  • Page 1: Important Safety Instructions

    146 Barr St, Saint-Laurent Units that are obviously damaged must not be operated. Quebec, CA, H4T 1Y4 1-888-726-8869 techsupport@sanuvox.com Installation Date: _______________ Installed by: _________________ Installer Contact Info.: _________________________________________ Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.2...
  • Page 2: Table Of Contents

    Step by Step Filter Replacement How to Replace Photo-oxydation Controller Head Step by Step Photo-oxydation Controller Head Replacement How to Clean your Product STORAGE ULTRAVIOLETS ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE TROUBLESHOOTING Problems & Solutions Table WARRANTY CUSTOMER SERVICE www.sanuvox.com 1-888-726-8869...
  • Page 3: About The Product

    The controller automatically turns a second lamp on and off to actively address the buildup or reduction of these odors. For information or recommendations on how to size your specific application, please call SANUVOX at 1-888-726-8869. COMPONENTS...
  • Page 4: Setup & Installation

    CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869. What’s included The SANUVAIR S300 OZD, a pleated 2"...
  • Page 5 6 screws provided for this purpose. STEP 9 9. Close the filters and motor access door of your SANUVAIR S300 ® OZD unit. You are now ready to install your SANUVAIR ® S300 OZD unit in one of the two suggested installation types. www.sanuvox.com 1-888-726-8869...
  • Page 6: Versatile Installations

    4. Then place an air inlet grid (sold separately) over the opening you made at the top: this grid will rest against the mounting angle to lock it in place. Do the same for the air outlet under the unit. Your are now ready to install your photo-oxidation controller. www.sanuvox.com 1-888-726-8869...
  • Page 7: Step By Step Installation | Added Ducts

    8" flexible pipe. Do the same for the air outlet under the unit. STEP 5 5. Install your 8" (rigid in aluminum or galvanized or aluminized flexible) pipes. Your are now ready to install your photo-oxidation controller. www.sanuvox.com 1-888-726-8869...
  • Page 8: Step By Step Installation | Photo-Oxidation Controller

    5. Turn the unit ON and wait approximately 1 tot 2 minutes for the startup phase to be completed, and for the OZD controller to calibrate. The second lamp should turn on (with the appropriate LED on the front plate). Your new SANUVAIR S300 OZD is now ready to ® operate! www.sanuvox.com 1-888-726-8869...
  • Page 9: Operation

    The Sanuvair S300 OZD’s LED Status Display will give you real time status update about ® your unit and its lamps. Normal Operation BALLAST ON, RED: Ballast in operation, "Default Mode". UV ON, AMBER: Lamp in operation, "Default Mode". www.sanuvox.com 1-888-726-8869...
  • Page 10: Maintenance

    ® and ballast access door (plate), remove and dispose of old lamps, replace with new Sanuvox branded UV lamps, screw back the lamp and ballast access door (plate) and turn power source back on. See below for detailed step by step instructions.
  • Page 11: How To Replace Filters

    STEP 3 3. Unpack the new filter and place it in the unit, then close the access door. NOTE: Make sure to install filters according to air flow direction for maximum performance. www.sanuvox.com 1-888-726-8869...
  • Page 12: How To Replace Photo-Oxydation Controller Head

    Once a year or as needed, clean the interior of the unit (wall and motor plate), with mild non-abrasive soap. It is recommended to use products that are environmentally friendly. CAUTION: Under no circumstance should water be sprayed or splashed onto the product. STORAGE The Sanuvair S300 OZD unit is fixed installation and therefore, requires no specific storage. ® www.sanuvox.com 1-888-726-8869...
  • Page 13: Ultraviolets

    (DNA/RNA) of microorganisms, which inactivates them. Unlike conventional UV lamps on the market, Sanuvox units and systems use a patented process that delivers a maximum dose of UV to the moving air stream or surfaces. CAUTION: Never expose eyes or skin to an operating UV lamp.
  • Page 14: Warranty

    This warranty applies only to the original purchaser of this product from the original date of purchase. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.

Table of Contents