READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in
this manual before using the product. Read the
maintenance instructions before opening the unit.
Failure to comply with these instructions may result
in personal injuries or damage to the unit or system.
1.
Installation and servicing of air conditioning and
related equipment can be hazardous due to systems
pressure and electrical components. Only trained
and qualified service personnel should install,
repair or service equipment.
2.
Untrained
personnel
can
maintenance functions such as replacing lamp(s)
and/or filter(s). All other operations should be
performed by trained service personnel.
3.
The unit is not to be used by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction.
CAUTION: Unit is not a toy. Do not leave children
unattended with the unit.
4.
Units that are obviously damaged must not be
operated.
Installation Date: _______________
Installer Contact Info.: _________________________________________
SANUVAIR
AIR SANITIZER PURIFICATION UNIT
Commercial Model

IMPORTANT SAFETY INSTRUCTIONS

5.
When working on the unit or system, observe
precautions in the literature, tags and labels attached
to the unit or system, and all other safety precautions
considered as best practices in the HVAC industry.
6.
When applicable, local regulation may comprise
more
restrictive
requirements. The afore mentioned requirements
prevail on those of this document and the installer
agrees to conform to these at his own expense.
7.
Follow all the safety instructions outlined in this
document and respect all local and national codes
perform
basic
applicable.
8.
This unit contains a UV-C emitter. Unintended use of
the unit or damage to the housing may result in harmful
UV-C radiation leaks. UV-C radiation may, even in little
doses, cause harm to the eyes and skin.
Never expose eyes or skin to ultraviolet light
9.
from any source. Therefore, before installing or
performing maintenance on the unit or system,
TURN OFF AND DISCONNECT the unit or system
from all power sources (there may be more than
one switch to disconnect).
CAUTION: Electrical shock may cause personal
injuries or possibly death.
Sanuvox Technologies Inc, © 2020 All rights reserved. November 2020 EN v.5
S100GX
®
10. UV rays may destroy certain types of filters (polymer
11. When installing or performing maintenance on the
installation
and/or
certification
12. UV lamps contain a small quantity of mercury: if a
13. Use
14. Most UV units or systems are not waterproof. DO NOT
Installed by: _________________
Instruction Manual
or plastic); please keep the unit or system light away
from shining directly on plastic.
UV unit or system, it is recommended to wear safety
glasses and gloves. In order to avoid reduced
performance of lamp(s), do not touch lamp glass
without gloves.
lamp breaks, clean and dispose of with care. UV
lamps can be disposed/recycled after use, as any
other fluorescent lamps. Contact and follow your local
and national authorities' specific instructions.
only
specified
SANUVOX
replacement UV lamps with your unit or system.
Use of any other lamps will void your warranty and
can result in damage to the unit, system and/or
lamp(s).
INSTALL OUTDOORS unless specified otherwise.
SAVE THESE INSTRUCTIONS
branded

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SANUVAIR S100GX and is the answer not in the manual?

Questions and answers

Summary of Contents for Sanuvox SANUVAIR S100GX

  • Page 1: Important Safety Instructions

    Units that are obviously damaged must not be operated. CAUTION: Electrical shock may cause personal injuries or possibly death. Installation Date: _______________ Installed by: _________________ Installer Contact Info.: _________________________________________ Sanuvox Technologies Inc, © 2020 All rights reserved. November 2020 EN v.5...
  • Page 2: Table Of Contents

    Instruction Manual for SANUVAIR S100 ® TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS TABLE OF CONTENTS ABOUT THE PRODUCT COMPONENTS How it Works SETUP & INSTALLATION What you will need What’s included Versatile Installations Step by Step Setup & Installation - Ceiling-Mounted Step by Step Setup &...
  • Page 3: About The Product

    ABOUT THE PRODUCT Congratulations on the purchase of your new Sanuvox UV air purifier. Sanuvox UV air purifiers are the most advanced air purification systems available, having been proven to destroy up to 99.99% of biological and chemical contaminants that circulate throughout the air of your home or facility.
  • Page 4: Versatile Installations

    Instruction Manual for SANUVAIR S100 ® Versatile Installations The SANUVAIR S100 unit can be installed two ways: ceiling-mounted in a 24" x 14" area of a suspended ceiling at least 8" ® deep OR simply wall-mounted. Either way, make sure there is adequate clearance (at least 2 feet) for the door to swing down for maintenance or service. CAUTION: The adapter cannot be installed in a dry wall ceiling.
  • Page 5 Instruction Manual for SANUVAIR S100 ® STEP 6 6. Install Filter: While the unit cover is still open, pull on the non-mesh end to gain access to the filter location (mesh door). Take the filter out of its packaging and install it in the unit. Close the mesh door properly. STEP 7 7.
  • Page 6: Step By Step Setup & Installation - Wall-Mounted

    Instruction Manual for SANUVAIR S100 ® Step by Step Setup & Installation - Wall-Mounted STEP 1 1. Check installation location of the unit, so that there is at least 24" from the ceiling in order to have good air circulation. min.
  • Page 7: Operation

    Instruction Manual for SANUVAIR S100 ® STEP 7 7. Adjust the fan speed: While the unit cover is still open, you will have access to the speed controller. For best results, choose “Hi” and for quieter use, choose “Low”. Once the lamp and filter are installed and the fan settings are adjusted to your liking, make sure to close the unit cover properly.
  • Page 8: Maintenance

    Instruction Manual for SANUVAIR S100 ® MAINTENANCE How to Replace Lamp(s) Replacing lamps on the SANUVAIR S100 needs to be done periodically to maintain design specifications. The UV lamp can ® function for many years, but over time, the UV wavelength does decrease. For best results, the UV lamp should be replaced every two years guaranteeing the highest performance.
  • Page 9: How To Clean Your Product

    Instruction Manual for SANUVAIR S100 ® How to Clean your Product There is very little maintenance to be done on the SANUVAIR S100. ® Periodic cleaning of the inlet filter may be performed. Filter media should be cleaned at least once every 6 months for optimal performance to be kept free of dust and residue deposit.
  • Page 10: Storage

    ULTRAVIOLETS: UVV & UVC The UVC (254 nm) and UVV (185 nm) light produced by Sanuvox UV units and systems are the same two UV wavelengths produced by the Sun. The UVC wavelength attacks the micro-organisms on a molecular level deactivating and destroying the contaminants, while the UVV wavelength degrades the chemicals and odors.
  • Page 11: Step By Step Uv Lamp Continuity Test

    Instruction Manual for SANUVAIR S100 ® Step by Step UV Lamp Continuity Test Example for a ceiling-mounted unit. The same step by step process applies for a wall-mounted unit. NOTE: Its possible to access the lamp while the unit is installed on the ceiling or wall. Another option is to remove the unit from the ceiling or wall, and then access the lamp with the unit lying on a flat surface with the access doors facing up.