INSTALLATION, MAINTENANCE & OPERATION GUIDE MODEL S300FX-GX WHOLE HOUSE HEPA/UV AIR PURIFIER...
Page 2
Follow all safety codes.Wear safety glasses and work gloves WARNING Before installing the S300FX-GX HEPA/UV Purifier or performing maintenance or service on the air purifier, disconnect power cord from the unit.
• Power cord, 5 FT • Plenum seal, 7.5 FT • Screws, (16) 8 x 32 x 1/2" • Template • Ultraviolet UVC/UVV Lamp J Type 10.5" (266.7 mm) • Pre-Filter • HEPA Filter SANUVOX - MODEL S300FX-GX - 3...
Page 4
432 mm Stage 2 Stage 2 Stage 2 13" 12" 13" 12" 17" 13" 12" 17" 17" 327 mm 305 mm 327 mm 305 mm 432 mm 327 mm 305 mm 432 mm 432 mm 4 - SANUVOX - MODEL S300FX-GX...
• Return duct to Return duct integrated with the forced air HVAC system. Cooling system • Central draw points using a dedicated duct system. • Respect the Minimum clearance • Consult Sanuvox for other special applications. requirements for maintenance and service • Electrical power requirements • Interaction between the HEPA/UV air purifier unit and other mechanical devices.
Stand Alone Wall Mount The Sanuvox S300FX-GX can be wall mounted using optional inlet and outlet louvers (Part # MSCLOU1) that attach to the collar mount port openings on the top and bottom of the unit.
Figure 2.2b - One cut permits the clean removal of the insulation piece. Figure 2.1b - Remove template. Figure 2.2c - The unit should look like this when the foam piece is removed. SANUVOX - MODEL S300FX-GX - 7...
Page 8
“Ducting Flairs” and screw the unit in place. Figure 2.2e Figure 2.2i Figure 2.2f Figure 2.2j - Bend tabs outward 90 degrees. Figure 2.2g 8 - SANUVOX - MODEL S300FX-GX...
Page 9
Figure 2.4b - Replace door and insert power cord into the receptacle of the HEPA and the other end into a wall outlet. SANUVOX - MODEL S300FX-GX - 9...
Page 10
STEP 1: The UV Lamp is packaged in the filter section of the S300FX-GX. Remove the UV lamp from the packaging material. The lamp is fragile, use extreme care. Do not touch the glass on the lamp with bare hands. Use the enclosed gloves when handling the lamp. Handle lamp from the ceramic ends.
OWNER’S OPERATION GUIDE 3. GENERAL OPERATING INFORMATION DOOR SWITCH FUNCTION The S300FX-GX HEPA/UV Purifier is designed The HEPA/UV air purifier is comprised of a to kill bacteria, viruses, odor causing mold and fungus as well as chemical odors and VOC's ventilator, speed selection switch, 2 stages of filtration and the cabinet enclosure system.
S300FX-GX UV Power Part # MSCMTR11 Supply cord for Door optional UV module Interlock Motor for S300FX-GX 120 volt Part # MSCMTR7 Motor for S300FX-GX 230 volt *Must be ordered with part# MSCCAP3 Capacitor. 12 - SANUVOX - MODEL S300FX-GX...
Page 13
2. Damage or repairs required as a consequence or faulty installation or without charge for the part itself, through a qualified servicing SANUVOX application by others. TECHNOLOGIES INC. dealer or distributor, PROVIDED the defective part is returned to our distributor.
Need help?
Do you have a question about the S300FX and is the answer not in the manual?