Sanuvox S300 Installer's Instructions

Voc for smoking room
Hide thumbs Also See for S300:

Advertisement

Quick Links

Box contains:
One (1) S300 VOC unit that includes:
o One (1) ''J'' lamp UVC/UVV with yellow tips (part LMPHGXJ105-1 2'' exposé)
o One (1) ''J'' lamp all UVV with blue tips (part LMPHXJ105)
o Two (2) Multi voltage ballasts (part BST120/277GL) and 2 lamp-holding brackets
o One (1) Relay (part MSCELC16) connected to the all UVV lamp
o Twenty (20) feet of wire that can be inserted in BX shield.
o One (1) VOC controller (part MSC1A) factory's pre-set
Two (2) replacement pre-filters (part MSCFTR10)
Controller
LAMP INSTALLATION
1. Remove the 6 screws on the front cover (The one with
the SANUVOX logo). Put aside.
2. Remove the BLUE END CAP lamp from packaging. Use
the gloves provided.
3. Insert the lamp in the second clamp and tighten.
(furthest clamp from opening)
4. Holding the cap with one hand, plug the white
connector tightly on the lamp
5. Remove the YELLOW END CAP lamp from packaging.
Use the gloves provided.
6. Insert the lamp in the first clamp and tighten. (closest to
opening)
7. Holding the cap with one hand, plug the white
connector tightly on the lamp
8. Put the cover back on with the 6 screws
S300 VOC FOR SMOKING ROOM
INSTALLER INSTRUCTIONS
For a 2400 cubic feet maximum smoking room
Casing
Wiring 20'
Relay

Advertisement

loading

Summary of Contents for Sanuvox S300

  • Page 1 For a 2400 cubic feet maximum smoking room Box contains: • One (1) S300 VOC unit that includes: o One (1) ‘’J’’ lamp UVC/UVV with yellow tips (part LMPHGXJ105-1 2’’ exposé) o One (1) ‘’J’’ lamp all UVV with blue tips (part LMPHXJ105)
  • Page 2 The VOC controller should be installed on the wall, at 12 inches from the ceiling where the smoke accumulates. The S300 VOC unit comes with 20ft of wire to link the controller box to the unit. If 20 ft not long enough, you can replace it with BX wiring with 3 wires.
  • Page 3 VOC CONTROLLER Remove the cover. Connect the 3 wires from the controller to the same color setting screw: wiring coming from the unit. Use the wire connectors triggers at 3.0 V DC included. Sensor Positive The detector is factory set a t 3.0 V DC; If you wish to set up a higher sensitivity, please proceed as follow.
  • Page 4 • The S300 VOC unit runs continuously, so its regular lamp purifies the air constantly. This dual zone lamp (UVC / UVV) is enough when there are only one or two smokers.