Sanuvox R1r Instruction Manual

Sanuvox R1r Instruction Manual

Whole home uv air purifier

Advertisement

Quick Links

REGISTER
YOUR WARRANTY
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit
or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
1.
Installation and servicing of UV units or systems (in an
air conditioning system or not) can be hazardous. Only
trained and qualified service personnel should install,
repair or service equipment.
Untrained personnel can perform basic maintenance
2.
functions such as replacing lamp(s) and/or filter(s). All
other operations should be performed by trained service
personnel.
3.
The unit is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge.
CAUTION: Unit is not a toy. Keep away from
unsupervised children. Do not leave children unattended
with the unit.
4.
DO NOT hang onto the UV unit or system.
5.
Some UV units or systems could be heavy: Make sure
you have a minimum of 2 people to safely move or install
these UV units or systems, and make sure you adopt the
most ergonomic position possible (use UV unit or system
handles, if applicable).
CAUTION: Installing or maintaining heavy equipment,
especially overhead, can cause back pain or other injuries.
6.
When installing or servicing an overhead UV unit or system,
be careful not to fall off the stepladder. Furthermore, make
sure the UV unit or system latches are always in place to
prevent falling parts.
CAUTION: Some parts of some UV units and systems
may open suddenly if the UV unit or system is installed
high up without its locks.
6.1.THIS AIR CLEANER SHALL NOT BE INSTALLED ON THE
HOT-AIR SIDE OF DUCT-TYPE SYSTEMS.
7.
Units that are obviously damaged must not be operated.
Installation Date: _______________
Installer Contact Info.: _________________________________________
WHOLE HOME UV AIR PURIFIER
Residential Model

IMPORTANT SAFETY INSTRUCTIONS

NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.
8.
CAUTION: When working on the UV unit or system,
observe precautions on the literature, tags and labels
attached to the UV unit or system, and all other safety
precautions considered as best practices in the HVAC
industry, if applicable.
9.
When applicable, local regulation may comprise more
restrictive installation and/or certification requirements.
The aforementioned requirements prevail on those of this
document and the installer agree to conform to these at his
own expense.
10. Follow all the safety instructions outlined in this document
and respect all local and national codes applicable.
11. All UV units or systems contain a UV-C source. Damage to
the housing or unintended use of the UV unit or system may
result in harmful UV-C leaks. UV-C may, even in little doses,
cause harm to the eyes and skin.
12. Never expose eyes or skin to an operating UV lamp.
Therefore, before installing or performing maintenance
on the UV unit or system, TURN OFF AND DISCONNECT
the UV unit or system from all power sources (there
may be more than one switch to disconnect) and also
disconnect the HVAC system, is applicable.
CAUTION: Electrical shock may cause injuries or
possibly death. FIRST AID INSTRUCTIONS: If injured,
consult a doctor.
12.1. To reduce the risk of electric shock, this equipment has a
grounding type plug that has a third (grounding) pin. This
plug will only fit into a grounding type power outlet. If the
plug does not fit into the outlet, contact qualified personnel
to install the proper outlet. Do not alter the plug in any way.
12.2. The product is to be located so that connection can be
made to the source of electrical supply without the use of
an extension cord.
Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.1
R1r
Installed by: _________________
Instruction Manual
13. UV rays may damage certain types of filters (polymer or
plastic); please keep the UV unit or system light away from
shining directly on plastic.
14. When installing or performing maintenance on the UV unit
or system, it is recommended to wear safety gloves. In
order to avoid reduced performance of lamp(s), do not
touch lamp glass without gloves.
15. Just like conventional fluorescent lamps, UV lamps contain
a small quantity of mercury: if a lamp breaks, clean and
dispose of with care. UV lamps can be disposed/recycled
after use in the same way as any other fluorescent lamps.
Contact and follow the specific instructions of your local
and national authorities.
15.1. Dispose of unit or system according to the specific
instructions and standards of your local and national
authorities.
16. Use only specified SANUVOX branded replacement
UV lamps for your UV unit or system. Use of any other
lamps will void your warranty and can result in damage to
the UV unit or system.
17. Sanuvox UV units or systems are not waterproof. DO NOT
INSTALL OUTDOORS OR IN WET LOCATION unless
specified otherwise.
18. Use of this unit or system supplements, but does not
replace, infection control best practices. Users must follow
all these practices, particularly with regard to cleaning and
disinfecting surfaces.
SAVE THESE INSTRUCTIONS
For any inquiries on a UV unit or system, contact :
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
techsupport@sanuvox.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R1r and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sanuvox R1r

  • Page 1: Important Safety Instructions

    Quebec, CA, H4T 1Y4 an extension cord. 1-888-726-8869 techsupport@sanuvox.com Installation Date: _______________ Installed by: _________________ Installer Contact Info.: _________________________________________ Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.1...
  • Page 2: Table Of Contents

    Instruction Manual for R1r TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS TABLE OF CONTENTS ABOUT THE PRODUCT COMPONENTS How it Works ACCESSORIES & KITS SETUP & INSTALLATION What you will need What’s included Step by Step Setup & Installation OPERATION How to Operate your Product...
  • Page 3: About The Product

    How it Works Foul air is exposed to the UV ‘J’ lamp of the R1r that is positionned parallel to the airflow, thus maximizing exposure time to UV light. The reflective mirror surface bounces additional UV energy into the plenum. The UV lamp helps reduce the biological contaminants.
  • Page 4: Setup & Installation

    What’s included The R1r unit, reflector, duct mount, a UV lamp, a 6' 24 VAC power cord and a basic installation kit. The installation kit includes: a UV caution decal, a pair of cotton gloves, sheet metal screws (4) and 6-32 nuts (3).
  • Page 5 Instruction Manual for R1r STEP 6 5. Unpack the R1r unit and reflector. 6. Fasten the reflector to the R1r unit using the 3 provided nuts and a 1/4" nutdriver. 7. Remove the lamp from its packaging. NOTE: Wear the provided cotton gloves for the following steps.
  • Page 6: Operation

    The R1r is an automatic unit: once it’s installed and plugged in, it immediatly turns ON on its own. CAUTION: The suggested operating temperature range is 10 to 66°C (50 to 150°F). Operating the R1r outside this range will result in decreased performance.
  • Page 7: Maintenance

    How to Replace Lamp(s) Replacing lamps on the R1r is quick and easy. Simply turn off the power source, remove unit from duct, remove and dispose of old lamp, replace with new Sanuvox branded UV lamp, replace unit in duct and turn power source back on. See below for detailed step by step instructions.
  • Page 8: How To Clean Your Product

    (DNA/RNA) of microorganisms, which inactivates them. Unlike conventional UV lamps on the market, Sanuvox units and systems use a patented process that delivers a maximum dose of UV to the moving air stream or surfaces. CAUTION: Never expose eyes or skin to an operating UV lamp.
  • Page 9: Troubleshooting

    NOTE: The R1r error code is determined by the LED flashing pattern on the ballast. The flashing pattern on the ballast is determined by the number of LED blinks (1 to 5) followed by a 1 second pause. This pattern will repeat over and over until the error code is cleared.
  • Page 10: Warranty

    This warranty applies only to the original purchaser of this product from the original date of purchase. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.

Table of Contents