Ac Power Supply Requirements For Grid Redundancy Of Cisco Mds 9718 Director - Cisco MDS 9700 Series Hardware Installation Manual

Hide thumbs Also See for MDS 9700 Series:
Table of Contents

Advertisement

Technical Specifications
Table 45: AC PSU Requirements for Grid Redundancy
Configurations
Up to 8 x Cisco MDS 48 Port 64-Gbps Fibre Channel Switching Modules
Up to 8 x Cisco MDS 48 Port 32-Gbps Fibre Channel Switching Modules
Any other supported module or a combination of supported modules:
• 48 Port 64-Gbps Fibre Channel Switching Module
• 48 Port 32-Gbps Fibre Channel Switching Module
• 24/10 port SAN Extension Module
• 24 Port 40-Gbps Fibre Channel over Ethernet Module
• 48 Port 16-Gbps Fibre Channel Switching Module
• 48 Port 10-Gbps Fibre Channel over Ethernet Module
AC Power Supply Requirements for Grid Redundancy of Cisco MDS 9718
Director
The following table lists the AC PSU Requirements for Grid Redundancy of Cisco MDS 9718 Director.
Table 46: AC PSU Requirements for Grid Redundancy
Configurations
Up to 16 x Cisco MDS 48 Port 64-Gbps Fibre Channel Switching Modules
Up to 16 x Cisco MDS 48 Port 32-Gbps Fibre Channel Switching Modules
Up to 12 x Cisco MDS 48 Port 32-Gbps Fibre Channel Switching Modules and
up to 4 x 24/10 port SAN Extension Module
Any other supported module or a combination of supported modules:
• 48 Port 64-Gbps Fibre Channel Switching Module
• 48 Port 32-Gbps Fibre Channel Switching Module
• 24/10 port SAN Extension Module
• 24 Port 40-Gbps Fibre Channel over Ethernet Module
• 48 Port 16-Gbps Fibre Channel Switching Module
• 48 Port 10-Gbps Fibre Channel over Ethernet Module

AC Power Supply Requirements for Grid Redundancy of Cisco MDS 9718 Director

Cisco MDS 9700 Series Switches Hardware Installation Guide
Minimum PSUs Required
for Grid Redundancy
4
4
6
Minimum PSUs Required
for Grid Redundancy
8
8
8
12
195

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9718Mds 9710Mds 9706