Setting Monitoring Options
The navigation pane at the top of the web browser interface contains a Monitoring tab that enables
you to manage your GS700TP Smart Switch with features under the following main menu options:
•
"Logs"
•
"RMON"
•
"Port Mirroring"
The description that follows in this chapter describes configuring and managing monitoring
settings in the GS700TP Smart Switch.
Logs
Event messages have a unique format, as per the SYSLOG RFC recommended message format for
all error reporting, for example, Syslog+ local device reporting. Messages are assigned a severity
code, and include a message mnemonic, which identifies the source application generating the
message. Messages are filtered based on their urgency or relevancy. The following table contains
the Log Severity Levels:
Table 7-1. Severity Levels
Severity
Severity Level Severity Level Description
Emergency
0
Alert
1
Critical
2
Error
3
Warning
4
Notice
5
The system is not functioning.
The system needs immediate attention.
The system is in a critical state.
A system error has occurred.
A system warning is logged.
The system is functioning properly, but a system notice is logged.
v1.0, April 2008
Monitoring the Switch
Chapter 7
7-1