GS700TP Smart Switch Software Administration Manual
Disable – Disable the Device Discovery protocol and stops the power supply to the
device using the PoE module.
Priority Level – Select the port priority if the power supply is low. The field default is
low. For example, if the power supply is running at 99% usage, and port 1 is prioritized as
high, but port 3 is prioritized as low, port 1 is prioritized to receive power and port 3 may
be denied power. The possible field values are:
Low – Set the PoE priority level as low. This is the default level.
Medium – Set the PoE priority level as medium.
High – Set the PoE priority level as high.
Class – Displays the classification of the powered device. The class defines the maximum
power that can be provided to the powered device. The possible field values are:
Class 0 – The maximum power level at the Power Sourcing Equipment is 15.4 Watts.
Class 1 – The maximum power level at the Power Sourcing Equipment is 4.0 Watts.
Class 2 – The maximum power level at the Power Sourcing Equipment is 7.0 Watts.
Class 3 – The maximum power level at the Power Sourcing Equipment is 15.4 Watts.
Class 4 – Treated as Class 0.
Output Voltage – Displays the Output Voltage in Volts.
Output Current – Displays the Output current in milliamps.
Output Power – Displays the Output power in Watts.
Power Limit – Displays the power limit in Watts.
Status – Displays the port's PoE status. The possible field values are:
Delivering Power – The device is enabled to deliver power via the interface.
Disabled – The device is disabled for delivering power via the interface.
Test Fail – The powered device test has failed. For example, a port could not be
enabled and cannot be used to deliver power to the powered device.
Testing – The powered device is being tested. For example, a powered device is tested
to confirm it is receiving power from the power supply.
Searching – The device is currently searching for a powered device. Searching is the
default PoE operational status.
3-12
v1.0, April 2008
Managing System Settings