1. Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all
power cords and external cables. Review the following information:
https://pubs.lenovo.com/safety_documentation/
• "Installation Guidelines", "Handling static sensitive devices", and "Power off the server " in User
Guide or Hardware Maintenance Guide.
2. Any system-board switch or jumper block that is not shown in the illustrations in this document are
reserved.
Figure 14. System-board switches
The following table describes the functions of the switches on the system board.
Table 10. System-board switches
Switches
Switch
block
number
1
2
3
4
SW1
1
5
6
7
8
ThinkEdge SE360 V2 System Configuration Guide
30
Switch name
XClarity Controller
The node boots by using a
boot backup
backup of the XCC firmware
CMOS clear
Clears the real-time clock (RTC)
registry
Password override
Overrides the power-on password
MFG mode
Enables MFG mode of firmware
(UEFI/XCC/FPGA)
XCC COM port
Enables XCC connection to the
serial port
Machine Engine (ME)
ME boots to recovery
recovery override
PCH PFR bypass
Enables PCH Flash to bypass
PFR
XCC PFR bypass
Enables XCC Flash to bypass
PFR
Usage description
On
Normal (default)
Normal (default)
Normal (default)
Normal (default)
Normal (default)
Normal (default)
Normal (default)
Normal (default)
Off