Troubleshooting
Condensing unit runs for long
periods of time.
Cabinet is noisy.
Cabinet Temperature Is too warm.
Excessive amount of warm
product Placed in cabinet.
Prolonged door opening or
door ajar.
Door gasket(s) not sealing
properly.
Dirty condenser coil.
Evaporator coil iced over.
Loose part(s).
Tubing vibration.
Thermostat set too warm.
Blocking air flow.
Excessive amount of warm
product Placed in cabinet.
Fuse blown or circuit breaker
tripped.
Dirty condenser coil.
Prolonged door opening or
door ajar.
Evaporator coil iced over.
For service call 1-800-465-0234.
10
Allow adequate time for
Product to cool down.
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
Ensure gaskets are snapped
in Completely. Remove gasket
and Wash with soap and water.
Check condition of gasket and
replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to
defrost. Make sure thermostat
is not set too cold. Ensure that
door gasket(s) are sealing
properly.
Locate and tighten loose
part(s).
Ensure tubing is free from
contact with other tubing or
components.
Set thermostat to lower
Temperature.
Re-arrange product to allow
for Proper air flow. Make sure
there Is at least four inches of
clearance from evaporator.
Allow adequate time for
product to cool down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time. (see
above)