RATING
RATING OF MIG400iCCCV INVERTER WELDING POWER SOURCE
CHARACTERISTICS
Input:
SUPPLY VOLTAGE, PHASE & FREQUENCY
MAXIMUM INPUT CURRENT
Output:
OUTPUT CURRENT RANGE
VOLTAGE RANGE
TYPE OF WELDING CURRENT CONTROL
CLASS OF INSULATION
COOLING
APPROX DIMENSION (LxWxH) IN MM
WEIGHT (APPROX)
INSTALLATION
The complete installation for MIG application should consist the following items:
Description
1.
Welding Power Source
2.
Wire feeder with
Interconnections, Wire
spool
3.
MIG Torch for MIG
4.
Earth cable with Clamp
5.
Heater - optional
6.
GAS with regulator
The complete installation for MMA application should consist the following items:
Description
1.
Welding Power Source
2.
Welding Cable with
Electrode Holder.
3.
Earth cable with Clamp
CONSTANT VOLTAGE/
CURRENT TYPE
415V± 15%, 3Phase, 50 Hz, AC
26.6 A
DC 40-400A
16-34 V DC
STEPLESS
'H'
FORCED AIR COOLED
654 x 322 x 671
50.5 KG.
Type
MIG400iCCCV
MIG400i wire
feeder
110V A.C. for CO
Type
MIG400iCCCV
5
Quantity
1
1
1
1
1
2
1
Quantity
1
1
1

Advertisement