AE Techron 7800 Series Operation Manual page 28

High-power, high-precision ac/dc linear power amplifier
Table of Contents

Advertisement

When Interlock (PIN 4) is shorted to Digital Ground 
(PIN 17), the amplifier is placed in Standby mode. 
When switch is open, the amplifier is released to 
the Run condition.
Signal Type: DC
Level when Asserted: 0 to 8 V
Level when Deasserted: 10 to 15 V
5.1.4 Remote Monitoring of Current
Using the SIM-BNC Interlock connector located on 
the back panel of the amplifier, you can remotely 
monitor current output.
Remote Monitoring of Current Output
Purpose: Use a voltage meter to monitor output
current.
Method: Connect a voltage meter to monitor
the output current being produced by the ampli-
fier. Connect across PIN 6 (I MON+) and PIN 10 
(Sampled Common). See Figure 5.5.
Signal Type: AC
Level when Asserted: 20A/V
Level when Deasserted: 0V
Remote Monitoring of Current Output -
Alternate Method
Purpose: Use a voltage meter to monitor output
current when output is not balanced.
Method: Connect a voltage meter to monitor
the output current being produced by the ampli-
fier. Connect across PIN 6 (IMON+) and PIN 19 
(IMON-). See Figure 5.6.
Signal Type: AC
Level when Asserted: 10A/V
Level when Deasserted: 0V
CAUTION: To avoid ground loops, isolation from
ground must be provided. Use of a differential 
probe is recommended.
28
IMPORTANT: The amplifier must be configured for 
Ready mode at startup (factory default) or the Run
button must be pressed at the amplifier module 
front panel at startup. The Remote Enable/Standby 
circuit will not function if the Startup to Standby
Latch has been activated on the amplifier.
Figure 5.5 – Remote Current Monitoring
Figure 5.6 – Remote Current Monitoring, 
Information subject to change
7800 SERIES OPERATION – SECTION 5
Alternate Method
96-8007105_07-14-23

Advertisement

Table of Contents
loading

Table of Contents