7800 SERIES OPERATION – SECTION 3
AC Power Connector - This is a NEMA style twist 
lock, 4 pin (208V) or 5-pin (400V), three-phase
connector.
Low-Voltage Fuse - This is a 1A slow blow type
600-volt rated fuse.
AC Mains Switch/Circuit Breaker - This dual
function power switch and circuit breaker opens all
legs of the AC mains.
Output Terminal Block - Connect output lines
from the load to this 4-terminal block on the Master 
amplifier module. The connector accepts up to #4 
AWG wire. If operating in Controlled Current mode, 
use the OUTPUT terminal and the SAMPLED 
COMMON terminal only.
96-8007105_07-14-23
BNC Input Connector - This input option provides
a standard unbalanced input.
Input Selector Switch - This switch selects which
input connector is active, the BNC or Weco.
Weco Input Connector - This input option pro-
vides a balanced input.
Interlock Connector - This 25-pin, D-sub con-
nector is used for interlocking amplifier modules 
to combine operating functions in a multi-amp
system. It can also be used for remote control and
monitoring applications (see the Applications sec-
tion for more information).