6.2 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Functions, press the ENTER button to
confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, the
present address will blink in the display, use the UP/DOWN button to adjust the address from 001 to
512, press the ENTER button to store. Press the MENU button back to the last menu or let the unit
idle 30 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Channel mode
16 channels
19 channels

6.3 DMX512 Configuration

Please control the fixture by referring to the configurations below
Attentions:
1. The unit will maintain the last condition until reset if you cut-off the DMX signal.
2. For the channel Function, keep the value for about 3 seconds, then the corresponding function
will take into effect.
16 Channels (Mode 1):
CHANNEL
1
2
3
4
Unit 1
Address
Address
1
1
VALUE
000-255
000-255
000-255
000-007
008-063
064-127
128-191
18E
Unit 2
Unit 3
Address
17
20
FUNCTION
PAN
0° 540°
TILT
0° 240°
PAN/TILT SPEED
Fast to Slow

SHOW MODE

Null
Show 1
Show 2
Show 3
Unit 4
Address
33
49
39
58

Advertisement