Summary of Contents for ACME Ellipsoidal

  • Page 2: Table Of Contents

    CONTENTS 1. Safety Instructions ..................2 2. Technical Specifications ................. 4 3. How To Set The Unit ..................7 3.1 Control Panel ................... 7 3.2 The Unit Construction ................8 3.3 Installation ....................8 4. Main Function ....................9 5. Control By Universal DMX Controller ............14 5.1 DMX512 Connection ................
  • Page 3: Safety Instructions

    1. Safety Instructions Please read the instruction carefully which includes important information about the installation, usage and maintenance. WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual. Important: Damages caused by the disregard of this user manual are not subject to warranty.
  • Page 4 Disconnect mains power before fuse replacement or servicing.  Replace fuse only with the same type.  In the event of serious operating problem, stop using the unit immediately.  Never turn on and off the unit time after time. ...
  • Page 5: Technical Specifications

    2. Technical Specifications Power Voltage: AC 100~240V, 50/60Hz Power Consumption: 335W Light Sources: HD320-B (E-300 MB CW) HD320-A (E-300 MB WW) HD320 (E-300 MB NW) Color Temperature: 5600±200K/3100±150K/4000K±150 Optical: CRI: WW≥90, CW≥85 CQS: WW≥91, CW≥88 TLCI: WW≥94, CW≥90 Control: DMX Channel: 1/2D/2 Channels Protocols: DMX, Primary/Secondary, manual dimmer Firmware Upgrade via DMX link Construction:...
  • Page 6 Dimension/Weight: 5°: 378x1155x524mm, 9.6kgs 14.9"x45.5"x20.6"in, 21.2lbs 11°/14°/19°: 276x872x524mm, 9.6kgs 10.9"x34.3"x20.6"in, 21.2lbs 26°/36°: 276x712x524mm, 9.1kgs 10.9"x28"x20.6"in, 20.1lbs 50°/70°: 276x637x524mm, 9.1kgs 10.9"x25"x20.6"in, 20.1lbs...
  • Page 7 Photometrics Diagram:...
  • Page 8: How To Set The Unit

    3. How To Set The Unit 3.1 Control Panel 1. DISPLAY: To show the various menus and the selected function 2. LED: PRIMARY Primary Mode SECONDARY Secondary Mode DMX input present 3. Button: MENU To enter into move backward or leave the menu To go backward to move up in the menu DOWN To go forward to move down in the menu...
  • Page 9: The Unit Construction

    3.2 The Unit Construction 1. Lens Module 2. Framing System 3. Bracket 4. Main Body 5. Clip for Gel Holder (Standard/Optional) 6. Gobo Slot 3.3 Installation Loosen the two screws on the Main Body (MB) and put the Framing System into the MB, then turn the Framing System right .Tighten the two screws to fix the Framing System.
  • Page 10: Main Function

    Put the Lens Module into the Framing System and tighten the Lens Module into the Framing System with two screws. 4. Main Function Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN button until the required function is shown on the monitor.
  • Page 12 DMX Address To select the DMX Address, press the ENTER button to confirm. Use the DOWN/UP button to adjust the address from 1 to 512. Once the address has been selected, press the ENTER button to setup, to go back to the functions without any changes, press the MENU button again. Hold and press the MENU button for one second or wait for 30 seconds to exit the menu mode.
  • Page 13 Pri./Sec. Mode To select the Pri./Sec. Mode, press the ENTER button to confirm. Use the DOWN/UP button to select Primary or Secondary. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes, press the MENU button again. Hold and press the MENU button for one second or wait for 30 seconds to exit the menu mode.
  • Page 14 Display Inverse Select Display Inverse, press ENTER button to confirm. Use the DOWN/UP button to select No (normal display) or Yes (inverse display), press ENTER button to store. Press MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode. Language Select Language, press ENTER button to confirm.
  • Page 15: Control By Universal Dmx Controller

    Firmware Version To select the Firmware Version, press the ENTER button to confirm and the display will show the software version of the unit. To go back to the functions without any changes press the MENU button again. Hold and press the MENU button for one second or wait for 30 seconds to exit the menu mode.
  • Page 16: Address Setting

    1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit.
  • Page 17: Dmx512 Configuration

    5.3 DMX512 Configuration Please refer to below configurations to control the fixtures Attentions: 1. The unit will maintain the last condition until reset if you cut-off the DMX signal. 2. For the channel Function, keep the value for about 3 seconds, then the corresponding function will take into effect.
  • Page 18: Troubleshooting

    6. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A. The unit does not work, no light and the fan does not work 1. Check the connect power and main fuse. 2.