Figure 22. System-board LEDs
Table 13. Description and actions for the system-board LEDs
LED
Fans 1-3 error LED
1 2 3
DIMMs 1-4 error LED (amber)
4 5 12 13
FPGA power status LED (green)
6
FPGA heartbeat LED (green)
7
Description and actions
LED on: an error has occurred to the fan the LED represents.
LED on: an error has occurred to the DIMM the LED represents.
The FPGA power LED helps to identify different FPGA errors.
• LED blinking rapidly (four times per second): The FPGA
permission is delayed.
• LED blinking slowly (once per second): the FPGA is read to power
on.
• LED on: The FPGA power is on.
This LED indicates power-on and power-off sequencing.
• LED blinking: the system is functioning properly, and no action is
necessary.
• LED not blinking: replace the system board (trained technician only).
See "System board replacement" in User Guide or Hardware
Maintenance Guide.
.