NI PXIe-4340 and TB-4340
4 Ch, 24-bit, 25.6 kS/s Simultaneous AC LVDT Input Module
This document explains how to install, configure, and set up the NI PXIe-4340 LVDT and RVDT
module with the TB-4340 terminal block. Driver support for the PXIe-4340 was first available
in NI-DAQmx 15.5. For the list of devices supported by a specific release, refer to the
NI-DAQmx Readme, available on the version-specific download page or installation media.
The keying of this terminal block prevents it from connecting to other
Note
modules that could be damaged by the voltage present on the terminal block.
However, you should only use these terminal blocks with their supported modules.
Contents
Electromagnetic Compatibility Guidelines .............................................................................. 2
What You Need to Get Started ................................................................................................. 2
Installation ................................................................................................................................ 3
Install the Software ........................................................................................................... 3
Unpack and Install the Module......................................................................................... 3
Connect the Signals .......................................................................................................... 5
Install the Terminal Block ................................................................................................ 8
Confirm PXIe-4340 Module Recognition ........................................................................ 9
Run Test Panels ................................................................................................................ 11
Take an NI-DAQmx Measurement .................................................................................. 11
NI-DAQmx Channels and Tasks.............................................................................. 11
Configure a Task Using the DAQ Assistant in MAX .............................................. 11
Use Your PXIe-4340 Module in an Application .............................................................. 12
Programming Examples ........................................................................................... 12
Terminal Block Removal.......................................................................................................... 13
Module Removal ...................................................................................................................... 14
Create a Simulated Device ....................................................................................................... 15
More Information ..................................................................................................................... 15
Troubleshooting................................................................................................................ 15
Specifications (TB-4340) ......................................................................................................... 15
Calibration ........................................................................................................................ 15
Electrical ........................................................................................................................... 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NI TB-4340 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments NI TB-4340

  • Page 1: Table Of Contents

    USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB-4340 4 Ch, 24-bit, 25.6 kS/s Simultaneous AC LVDT Input Module This document explains how to install, configure, and set up the NI PXIe-4340 LVDT and RVDT module with the TB-4340 terminal block. Driver support for the PXIe-4340 was first available in NI-DAQmx 15.5.
  • Page 2: Electromagnetic Compatibility Guidelines

    Furthermore, any modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules.
  • Page 3: Installation

    The module is static sensitive. Always properly ground yourself and the Caution equipment when handling or connecting to the module. NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 3...
  • Page 4 Complete the following steps to install the PXIe-4340 module while referring to Figures 1 and 2: To maintain forced air cooling in the PXI Express system, refer to the Note Maintain Forced-Air Cooling Note to Users. Plug in your chassis before installing the PXIe-4340. The power cord grounds the chassis and protects it from electrical damage while you install the module.
  • Page 5: Connect The Signals

    Prepare the shielded signal wire by stripping the insulation no more than 7 mm (0.28 in.). Run the shielded signal wires through the strain-relief opening. NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 5...
  • Page 6 Figure 3. TB-4340 Parts Locator Diagram Strain-Relief Screws Ground Lugs Top Cover Strain-Relief Bar Terminal Block to Module Connector Tie Wraps Tie Wrap Holes Captive Top Cover Screws Shielded Signal Wires Insert the stripped end of the shielded signal wires fully into the appropriate terminal. Refer to the label next to each screw terminal to determine the function of the terminal.
  • Page 7 Use tie wraps to connect the shielded signal wires to the tie-wrap holes for additional strain relief when necessary. 10. Reinstall the top cover and tighten the captive top cover screws. For information about sensors, go to Note ni.com/sensors NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 7...
  • Page 8: Install The Terminal Block

    Install the Terminal Block Refer to Figure 5 to install the terminal block on the module while completing the following steps: Move the TB-4340 into position in front of the PXIe-4340 and engage the alignment feature with the guide on the associated module. Figure 5.
  • Page 9: Confirm Pxie-4340 Module Recognition

    If your module or terminal block is not listed, press <F5> to refresh MAX. If the module is still not recognized, go to ni.com/support/ daqmx NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 9...
  • Page 10 Using an NI-DAQmx simulated device, you can test NI-DAQmx applications without installing hardware. Refer to the Create a Simulated Device section for instructions for creating NI-DAQmx simulated devices. Right-click the module name and select Self-Test. When the self-test completes, a verification message appears.
  • Page 11: Run Test Panels

    In MAX, right-click Data Neighborhood and select Create New to open the DAQ Assistant. Select NI-DAQmx Task and click Next. Select Acquire Signals. Select the measurement type, such as Analog Input - Position - LVDT. NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 11...
  • Page 12: Use Your Pxie-4340 Module In An Application

    NI-DAQmx includes example programs to help you get started developing an application. LabVIEW and CVI examples are located at Help»Find Examples in your application software. Text-based code examples are located at All Programs»National Instruments»NI-DAQmx» Text-Based Code Support. Modify example code and save it in an application, or use examples to develop a new application or add example code to an existing application.
  • Page 13: Terminal Block Removal

    Figure 7. Removing the TB-4340 from the PXIe-4340 Module Mounting Screw PXI Express Controller TB-4340 Terminal Block Latch Release PXI Express Chassis Store the terminal block in an antistatic protective bag. NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 13...
  • Page 14: Module Removal

    Module Removal Do not remove a module with the power on. Doing so can damage the Caution module. To remove the module, refer to Figure 8 while completing the following steps: To maintain forced air cooling in the PXI Express system, refer to the Note Maintain Forced-Air Cooling Note to Users.
  • Page 15: Create A Simulated Device

    All performance specifications are typical unless otherwise noted. These specifications are valid within the full operating temperature range. Calibration Calibration interval ........... No calibration Electrical Input range............Refer to NI PXIe-4340 Specifications document NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 15...
  • Page 16: Mechanical

    Mechanical Screw terminal wire gauge .......1.5 mm (16 AWG), max Physical Characteristics Figure 9. TB-4340 Dimensions 12.95 cm (5.10 in.) 15.28 cm (6.02 in.) Weight TB-4340 ............609 g (21.5 oz) Clean the hardware with a soft, nonmetallic brush. Make sure that the Caution hardware is completely dry and free from contaminants before returning it to service.
  • Page 17: Storage Environment

    Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 17...
  • Page 18: Electromagnetic Compatibility

    Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity • EN 55011 (CISPR 11): Group 1, Class A emissions •...
  • Page 19: Worldwide Support And Services

    For telephone support outside the United States, visit the Worldwide Offices section of to access the branch office websites, which provide up-to-date contact ni.com/niglobal information, support phone numbers, email addresses, and current events. NI PXIe-4340 and TB-4340 User Guide and Terminal Block Specifications | © National Instruments | 19...
  • Page 20 NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.

This manual is also suitable for:

Ni pxie-4340Tb-4340Pxie-4340

Table of Contents