Operating Instructions
Controller for vibratory drive systems
SCU1000
ESG1000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ESG1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for RNA ESG1000

  • Page 1 Operating Instructions Controller for vibratory drive systems SCU1000 ESG1000...
  • Page 2: Table Of Contents

    3.5. Releasing the function by external components ..............7 3.6. Canging the soft start time ..................... 7 Plan showing the position of the operating elements on the boards ........8 Scale Drawing ........................9 Connecting Diagram ......................9 Rhein-Nadel Automation GmbH VT-BA-ESG1000-EN-2020 / 07.10.2020 SJ...
  • Page 3 We hereby declare that the product meets the following requirements: Low-Voltage Directive 2014/35/EC Electromagnetic Compatibility Directive 2014/30/EU Applied harmonised standards: DIN EN 60204 T1 EN 61439-1 Remarks: Rhein-Nadel-Automation --------------------------------- Managing Director Jack Grevenstein Rhein-Nadel Automation GmbH VT-BA-ESG1000-EN-2020 / 07.10.2020 SJ...
  • Page 4: Technical Data

    Functional description The compact design of the control unit can supply all RNA-control units up to a load current of 6 ampere. It is intended for individual installation directly at the oscillating drive and completely pluggable. The correcting range for the potenti-...
  • Page 5: Safety Notes

    At initial starts or starts after repair work or exchange of control units/oscillating drives the minimum output should be set at the control unit before switching on the device. When bringing up the output it must be taken care for correct function. Rhein-Nadel Automation GmbH VT-BA-ESG1000-EN-2020 / 07.10.2020 SJ...
  • Page 6: Explanations On The Term Operating Mode

    3.1. Explanations on the term OPERATING MODE RNA - Oscillating drives are mechanical spring vibrators, which, according to weight and/or size, are adjusted to an oscillating frequency near the mains frequency. Two operating modes are possible: 1. Asymmetrical half-wave operation - the oscillating drive operates with mains frequency.
  • Page 7: Setting The Minimum And Maximum Output Voltage

    At the trimmer SOFT START the run-up time can be adjusted. As the case must be opened for this change as well, the safety notes mentioned above should be ober- served. Rhein-Nadel Automation GmbH VT-BA-ESG1000-EN-2020 / 07.10.2020 SJ...
  • Page 8: Plan Showing The Position Of The Operating Elements On The Boards

    10- and 30-volt direct current in correct polarity. The input is protected against faulty polarity. The use of an optocoupler in the control unit makes the input potential-free and allows the installation with unscreened cables of nearly any length. Here too high-energy interferences should be avoided Rhein-Nadel Automation GmbH VT-BA-ESG1000-EN-2020 / 07.10.2020 SJ...
  • Page 9: Scale Drawing

    5. Scale Drawing 6. Connecting Diagram Rhein-Nadel Automation GmbH VT-BA-ESG1000-EN-2020 / 07.10.2020 SJ...
  • Page 10 Fax: +41 (0) 62 956 10-10 E-mail: info@handling-systems.ch www.handling-systems.ch Manufacturing and Sales Pol. Ind. Famades c/Energia 23 E-08940 Cornella de Llobregat (Barcelona) Spain Phone: +34 (0)93 377-7300 Fax:: +34 (0)93 377-6752 E-mail: info@vibrant-RNA.com www.vibrant-RNA.com www.vibrant.es Rhein-Nadel Automation GmbH VT-BA-ESG1000-EN-2020 / 07.10.2020 SJ...