Summary of Contents for RNA ESR 2500

  • Page 1 Operating Instructions Controller for vibrating motors ESR 2500 ESR 2800...
  • Page 2: Table Of Contents

    5.3.1. The "Status" screen: ......................16 5.3.2. The "Info" screen: ......................17 5.3.3. The "Extended" screen: ..................... 17 5.3.4. Summary of ESR 2500, ESR2800 main menu ..............18 The set-up menu ....................... 18 6.1. List of set-up menu items ....................18 6.1.1.
  • Page 3 Technical data ........................28 9.1. Accessories ........................29 Alarm messages ........................ 29 10.1. Alarm message and troubleshooting ................. 29 10.1.1. Short-circuit protection active .................... 29 10.1.2. Overload protection active ....................30 10.1.3. No feeder or low current ....................30 10.1.4. Frequency error ......................... 30 10.1.5.
  • Page 4: About This Document

    1. About this document Attention Read this document carefully and observe the safety directives before commencing any work. The information given in this document reflects the following version: Product from software version Date ESR2500 V1.2.7 2019-03-01 ESR2800 V1.2.7 2019-03-01 Document description: This document provides assistance in choosing your product.
  • Page 5: Intended Use

    • Use of the product in living areas may lead to EMC disturbance. The user is responsible for taking interference suppression measures. • They are optimised for operation of RNA bowl feeders and linear feeders. Observe the limits indicated in the technical specification.
  • Page 6: Degree Of Protection - Protection Of Persons And Equipment

    3. Product information 3.1. Functional description This fully automatic controller has been developed specifically to operate RNA bowl feeders or linear feeders with a high feed rate. The intelligent controller continuously monitors the mechanical conveyor movement and uses this signal for active control of the vibration amplitude and thus the feed rate.
  • Page 7: Applied Standards

    3.3. Applied standards EC - Conformity The controller is compliant with the following standards: EC EMC Directive 2014/30/EU EC Low-Voltage Directive 2014/35/EU Applied harmonised standards: DIN EN 60204, part 1 EN 61439-1 4. Installation and commissioning This chapter deals with the mechanical and electrical installation of the controller. The controller is designed for quick and easy installation by following the sequence of operations below.
  • Page 8: Mechanical Installation

    4.2. Mechanical installation Planning the place of installation: Choose the best possible position taking the following into consideration: • Ambient temperature • Low-vibration mounting • Operator access to controller • Controller location near the vibrating motor • Cable routing 166,00 227,50 14,00 156,00...
  • Page 9: Commissioning

    Attention Before you connect the controller to power supply and switch it on, it is mandatory to check the following: • Is the controller in a good, safe operating state and closed with all screws tightened? • Are the connectors screwed in place/locked? •...
  • Page 10 Attention Before opening the controller, pull the mains plug and wait for the periods shown below, allowing the DC link circuit capacitors to discharge down to a safe voltage level. Discharge period: ESR 2500 10 minutes ESR 2800 15 minutes Rhein-Nadel Automation GmbH VT-BA-ESR2500-2800_EN-2020 / 09.04.2019 SJ...
  • Page 11 SRHL - 400 - 2 Black 45…60 Hz SRC - N 630 - 1 45…60 Hz SRC - N 800 - 1 Table 2 - RNA bowl feeders Motor type of lin- Max. current Max. coil gap [mm] Frequency range Magnet colour...
  • Page 12: Sensor Connection

    4.6. Sensor connection Sensor input and sensor connection The controller has two sensor inputs which can be used for accumulation checking and/or level monitoring purposes. You can connect sensors of type NPN or PNP. Rhein-Nadel Automation GmbH VT-BA-ESR2500-2800_EN-2020 / 09.04.2019 SJ...
  • Page 13: Connection Diagram

    4.7. Connection diagram Rhein-Nadel Automation GmbH VT-BA-ESR2500-2800_EN-2020 / 09.04.2019 SJ...
  • Page 14: Voltage Change

    4.8. Voltage change The ESR2500/2800 can be operated with various supply voltages and magnet voltages. For changing the voltage you must open the controller. Therefore, be sure to observe the safety instructions and general warning notices in Chapter 2. You can set the controller to a mains supply voltage of 230V or 115V. If set to a mains supply voltage of 230V the magnet voltage is always 200V.
  • Page 15: Operator Panel And Display Of The Controller

    5. Operator panel and display of the controller 5.1. Operator panel - Display The operator panel of the ESR2500/2800 controller comprises four buttons and a 2x16 digit display. Speed 100 % A Stopped The functions assigned to the buttons are as follows: ON / OFF is used to switch the connected feeder on and off.
  • Page 16: Navigating Through The Menus

    5.2. Navigating through the menus There is 1 main menu and 2 submenus for operating the ESR2500/2800 controller. From the main menu you can en- ter the set-up menu or the calibration menu by entering the required password. Use the arrow buttons for navigation through the menu screens. The menus are circular so that navigation beyond the last screen of a menu will take you back to the first screen and vice versa.
  • Page 17: The "Info" Screen

    The set speed determines the vibration amplitude. The controller operating mode is indicated to the right of the speed percentage by M for manual mode or A for auto- matic mode. In Manual mode the speed is indicated in percent of the maximum output voltage. When the controller is calibrated and you switch the mode to Auto the speed is shown as a percentage of the maximum calibrated speed.
  • Page 18: Summary Of Esr 2500, Esr2800 Main Menu

    5.3.4. Summary of ESR 2500, ESR2800 main menu A - Automatic M - Manual Blank - speed manual Speed - speed high - speed low - analogue input active >AN - field bus active – stopped by button – feeder running Blank –...
  • Page 19: Accumulation Checker (Sensor Inputs)

    6.1.1. Accumulation checker (sensor inputs) You can connect up to two sensors to "sensor connection" XS2 for accumulation monitoring or level monitoring. See connection diagram in chapter 4.6 and 4.7. The signal may, e.g., come from a light barrier indicating whether an accu- mulation section is full or not.
  • Page 20: Display Calibration

    6.1.3. Display calibration You can configure the display on the controller as required. In the Display Calibration menu item you can set the contrast/brightness. When lighting is set at "Normal" pressing of a button illuminates the display and after 10 seconds the light extinguishes again. When lighting is set to "On" the light remains on and if set to "Off"...
  • Page 21: Analogue Speed Input

    6.1.5. Analogue speed input Speed setting (0-100%) can be controlled from an analogue source that can be set at 0-10V, 0-5V or 4-20mA. The connection is of the clamping type and located at the right-hand side in the controller, see chapter 4.7 and 4.8. Parameter description Output parameter Range...
  • Page 22: Active Braking

    6.1.8. Active braking The active brake prevents a feeder vibration stop delay once the feeder is stopped. This option is particularly useful where counters are involved. Once the feeder has been stopped, feeding of further parts is to be avoided to the extent possible.
  • Page 23: Fine Tuning

    7.1.2. Fine tuning Fine tuning of the minimum and maximum speeds is mandatory after successful calibration. Take great care in fine tuning because otherwise the controller cannot operate the vibratory drive in the proper way, see chapter 7.2. After the speeds you can also adjust damping, if required. The speed and damping values can also be adjusted later on without the need for re-calibration.
  • Page 24: Calibration Process

    7.2. Calibration process In order that the controller works perfectly with the vibratory feeder connected, it must be calibrated to suit the feeder. After calibration, the determined calibration parameters are saved and re-loaded automatically every time the control- ler is started. Before calibration, set the correct current range;...
  • Page 25 After successful calibration proceed with fine tuning. Should one or several errors occur during the calibration process any such errors will be shown on the display. Press Enter to accept an error and the go to the next error, if any Proceed with fine tun- Calibration starts...
  • Page 26 Fine tuning of minimum speed Here you set the minimum speed at which the feeder is to run. Place some parts into the bowl, start the feeder using the ON/OFF button and set the minimum speed using the arrow buttons. The parts in the bowl must move slowly. It is particularly important to make sure that the feeder runs smoothly for at least 10 seconds.
  • Page 27 Set damping Here you can set damping of vibration amplitude control. If the feeder overshoots on starting or if speed setpoint changes cause vibration amplitude fluctuations it is advisible to set the value a little higher.If such cases do not hap- pen with your feeder but it responds slowly to load changes we would recommend to set the value a little lower.
  • Page 28: Memory Reset

    8. Memory Reset Attention This resets all parameters to the default values! Resetting to default values In order to reset the controller to the factory settings open the power switch to disconnect the supply voltage and wait for the display to darken. Now press and hold down the two "up" and "down" arrow buttons and then switch-on supply voltage again.
  • Page 29: Accessories

    Notice Supply voltage and load voltage must be set-up by hardware change in the controller; see chapter 4.5 and quick guide in the controller. 9.1. Accessories Designation Type RNA Mat.No. Connector 5-pin 31002329 Coupling plug 5-pinstraight 35051144 Coupling plug 5-pinangled...
  • Page 30: Overload Protection Active

    10.1.2. Overload protection active This alarm comes up if the load current exceeds twice the value of the maximum r.m.s. current. In this case the con- troller disconnects the output voltage immediately to protect the output stage against overload. The alarm message remains on the display until it is reset by Enter.
  • Page 31: Vibration Restricted

    10.1.5. Vibration restricted This alarm appears if the controller cannot maintain the required speed (vibration amplitude) without overloading the oscillating magnets. This alarm message appears if the feeder speed is less than half the set speed but the feeder draws the full current. This is not necessarily a malfunction;...
  • Page 32: Offset Error Refusing Common Mode, Distance Measurement

    Attention Before opening the controller, pull the mains plug and wait for the periods shown below, allowing the DC link circuit capacitors to discharge down to a safe voltage level. Discharge period: ESR 2500 10 minutes ESR 2800 15 minutes Device starts and display shows "Ready"...
  • Page 33 Further manufacturing sites RNA Group of the RNA Group Headquarters Manufacturing and Sales Manufacturing Lüdenscheid branch Rhein-Nadel Automation GmbH Rhein-Nadel Automation GmbH Reichsweg 19-23 Nottebohmstraße 57 D-52068 Aachen D-58511 Lüdenscheid Phone: +49 (0) 241-5109-0 Phone: +49 (0) 2351 41744 Fax: +49 (0) 241-5109-219 Fax: +49 (0) 2351 45582 E-mail: vertrieb@RNA.dede...