2.32
Transducers
for TNC 150 BR / TNC 150 OR
For cable lengths between
transducers
and control
which
exceed 20 m or for transducers
which
exceed
3040 mm, the control
versions
TNC 150 BR / TNC 150 OR al-e used.
2.3.2.1
Transducers
and EXE-units
for the X, Y, Z-axes
Transducers
for the main axes X, Y, Z are connected
to the control
via 3-axis EXE-units
with
separate
voltage
supply.
The following
combinations
are available:
Signal subdivision
Gratiing pitch of
NC-Linear
transducer
transducer
25-fold
100 urn
LB 326
5-fold
20 Urn
LS 107, LS 703, LS 903
1
25;fold
1
IOO~m
1 LB 326
Rotary
encoders
may also be used instead of linear transducers.
'
The max. cable length between
EXE 8 . . and TNC 150.R
is 50 m and 20 m between
the transducer
and the
EXE. The total cable length is therefore
70 m.
2.3.2.2
Transducers
and EXE-units
for axis IV
Subdivision
within
the pulse shaping electronics
is always
5-fo:d.
a)
Control
of a rotary
axis
Rotary
encoder
with
18 000 or 36 000 lines
ROD 250 /ROD
700
ROD 250 / ROD 700
ROD 800
ROD 271
EXE, with
subdivision
max. 'cable length EXE / TNC
801, 5-fold
602, 5-fold
50 m Connecting
cable
1 m c#able on EXE t-
9 m extension
'x.
,
602, 5-fold
1 m c,able on EXE,
No extension
!
Pulse shaping stage
within
ROD
1 m cable on ROD -1
9 m extension
When using a rotary
encoder
with
integral
pulse shaping electronics
or the pulse shaping electronic
unit
EXE 602, the voltage supply
is provided
by the TNC 150 R.
In order to maintain
the correct
supply
voltage,
the total lengtl
of the connecting
cable between
EXE 602
and the control
is limited
to 10 m.
When using an ROD 800 in conjunction
with
an EXE 602, an extension
cable between
EXE 602 and the control
should
not be used.