HEIDENHAIN TNC 150 B Mounting Instructions page 18

Contouring control
Hide thumbs Also See for TNC 150 B:
Table of Contents

Advertisement

b)
Analogue
voltage output
of spindle speeds
outputs
Spindle analogue voltage
f. 10 volts
0 volt
Gear ratio 1
2
3
4
5
6
7
8
S-Strobe
Auxiliary
function
completed
Caution
PLC-Allocation
-
-
A7
A8
A9
A10
All
Al2
Al3
Al4
A20
El7
TNC 150 H
Multipoint
connector
TNC 150 Q
Multipoint
connector
PLC-
Power
board
TNC 150 Q
Multipoint
connector
Control
J4/9
-
J1/9
J4/10
-
Jl/lO
J2/2
Jll8
-
J2/3
J1/9
-
J2/4
Jll9
-
J2/7
-
J2/8
-
J2/9
-
J3/3
-
J5/6
The O-volt nominal
value output
must be grounded
(see sectiol
3.13 Wiring).
For activation
of the spindle
with
DC-servodrive,
the control
provides
a DC voltage of 0 to + 10 volts. The polarity
of the output
voltage is
determined
by parameter
MPI 72. With the aid of machine
parameters
78 to 85, up to 8 gear ratios may be
defined.
This should
be commenced
with
the entry
of the ratio with
the lowest
speed. The max. voltage at the
input of the servo-amplifier
which
is programmed
with
machine
parameter
8,7. The S-gating signal is provided
with
each gear ratio.
After
verification
of the feedback
signal "auxiliary
function
completed"
and spindle status MO3 or M04, the
nominal
value voltage with
the ramp as programmed
with
maciine
parameter
168 are output.
No nominal
value
voltage output
takes place with
M05.
The nominal
value voltage for the spindle
drive during
gear change is determined
with
MP70.
For the duration
of gear change, the polarity
of this voltage MP70 is switched
o>/er in accordance
with
parameters
124 and 125.
The control
is fitted
with
an S-override
potentiometer.
The min. and max. voltage values can be programmed
with
machine
parameters
(Nos. 86 to 89 and 184).
3.5
Emergency
Stop
In/Output
Emergency
Stop (Output)
Emergency
stop-test
( Input)
PLC-Allocation
TNC 150 B
TNC15OQ
Multipoint
Multipoint
connector
connector
PLC-Power
board
-
J1/8
J3/10
E8
J5/8
J4/4
Important
functions
of the TNC 150 are under constant
supenlision
through
self-diagnostics
(electronic
subassemblies
such as microprocessors,
the memory
read/write-store,
positioning
systems,
transducers
etc.).
If
a fault is detected,
it is indicated
as a flashing
display
in the plain language dialogue.
On output
of fault-
indication,
the "emergency
stop"
contact
opens.
The "Emergency
Stop"
condition
of TNC 150 can only be carcelled
by switching
off the mains voltage-provided
that the fault has been rectified.
A special mains switch
may be necessary
for the control
only!
The emergency
stop contact
must cut-out
the 24 V auxiliary
voltage
in the machine
interface.
Due to the
significance
of the emergency
stop contact
for safety
reasons,
its function
is monitored
by the control
with
each
switch-on
of power
(see flow
chart).
18