2.2
Specific
data for KNC 150 0
Nominal
values and tolerances
External
voltage supply
for PLC
Nominal
voltage:
24 V, -
Voltage
range: 20.4 V to 28.8 V
Furthermore,
superimposed
alternating
voltages with
a relative oscillation
width
of 10 % - related to the average
DC-voltage
value - are permissible.
Circuitry
example:
Definition:
+2&V
fi = DC-voltage
average: 20.4.
. . 28.8 V
AU
= Oscillation
width:
-= 10 % related to u
.h
Y
"
t
Au
toPLl00B/ll0B
1
Yj
Binary
input signals
(EO to E62 and E64 to E 126)
Nominal
voltage:
24 V, -
Voltage
range for signal "1":
16.5 V to 30 V
Voltage
range for signal "0":
- 3 V to + 4 V
Current
range for signal "1":
6.2 mA to 12.6 mA
Please note:
Interference
signals ~1 rns at the PLC-inputs
are filtered
with
a Schmitt-Trigger-input
circuit.
Long duration
interference
signals must be with
software.
Binary
outputs
signals (PL 100 B: A0 to A30, A32 to A62; PL 1 IO B: A0 to A24, A32 to A56 and "Emergency
stop")
Nominal
voltage:
24 V, -
Max. difference
to supply
voltage:
L 3 V
Max. output
current:
1.2 A
Permissible
loading:
Resistive
load; inductive
load only parallel to inductivity
with
quenching
diode, max.
switching
frequency:
50 Hz
Please note:
Adjacent
PLC-outputs
(e.g. A7 with
A8) can be switched
to parallel via resistors
e.g. 2 x 0.472.
+
max
2,1, A
6