6.1.6
Machine
parameters
for other functions
Function
Parameter
Possible
Selected
No.
entry
values
entry values
Resolution
65
0
L
1 v-n
1
n =
51-rr-n
With parameter
65 the resolution
of TNC 150 can be programmed
for either
1 ym or 5 urn.
For optimization
of machine
parameters,
1 urn is used. The 5 pn resolution
is usually
sufficient
for normal
machine
operation.
Signal evaluation
;
~~~
With these parameters,
the signal evaluation
for the transducers
can be reduced
from 20-fold
to IO-fold.
Standstill
supervision
169
0.001 to 30 mm
Parameter
169 determines
the range in which
non-controlled
axes may move without
activition
of a fault
detection
signal.
lff-line programming
station
170
0
h =
Control
1
n =
Off-line
programming
station
PLC active
2
A =
Off-line
programming
station
PLC inactive
Parameter
170 determines
whether
the control
is intended
as an off-line
programming
station
or not. If
parameter
170 is programmed
with
1 or 2, the control
requires
170 transducers
or external
circuitry.
The "scaling"
to 2 or 3 axes
I
-
Programmed
stop with
MO6
I214
40
0
e
The programmed
scaling factor
is
effective
in the 3
main axes X, Y, Z
1
* =
The programmed
scaling factor
is
effective
in the
working
plane
0
-
$
Programmed
stop
with
MO6
1
* II
No programmed
stop with
MO6