The TNC 150 is equipped
with
"software-limit
switches".
The permissible
travels
of the machine
axes are
programmed
as machine
parameters
with
reference
to the location
of the reference
mark of the specific
transducer.
(See "Software
limit switch"
, section
3.7 ).
After
switching
on the mains power
of the TNC 150, the refl?rence points
of all three machine axes must be
traversed
over. After
pressing the external
Start-button,
traversing
over of the reference
points
is performed
automatically
as per the entered
machine
parameters.
Please note: After
entry
of the code number
84 159 in the MOD-mode
the reference
points
can also be traversed
over by means of the external
direction
buttons.
For location
of reference
points
it is necessary
for each machine
axis to have a cam-switch
("Reference
end
position").
The cam for this switch
must be positioned
such, that when travelling
towards
the cam, the switch
closes shortly
before
reaching
the reference
point and remains
closed whilst
still traversing
in the same
direction
until the emergency
stop switch.
A rotary
table axis is an exception.
For this axis, a permanent
bridge
from J5/12
(TNC
150 B) or J4/9 (TNC
150 Q) to +24 V is required.
3.6.1
Location
of "Reference
end position"
- cam when using linear transducers
(Inputs
for "Reference
pulse-inhibit"
are not required
and remain disconnected).
max. travel of axis
A--
Range between
emergency
stop
switches
II-
measuring
length
al
Linear transducer
I
Reference
point position
Cam switch
"Reference
end position"
closed
I
open
Switch
"Reference
end position"
3.6.2
Location
of "Reference
end position"
and "Referenc:e
pulse inhibit"
- cams when
using rotary
encoders
With installation
of rotary
encoders,
an additional
cam switc:h
per axis is necessary
for reference
pulse
suppression.
A rotary
encoder
produces
one reference
pulse per revolution,
e.g. a spindle
pitch of 10 mm will, after
10 ms
of travel, transmit
one reference
pulse. The control
will evalllate a reference
pulse only when the cam switch
"reference
end position"
is closed and cam switch
"reference
pulse inhibit " is open. In the example,
the cam
must be adjusted
such, that the switch
opens 5 mm before tie desired
reference
pulse and closes approx.
5 mm
after the reference
pulse.
max. travel of axis
Range between
emergency
stop
Lr
switches
I
1
IA
A
A
A
L/\
=
I>
Possible reference
pulses from
rotary
encoder
desired
reference
pu Ise
Cam switch
"Reference
end position"
closed
I
I
II
open
Switch
"Reference
end position"
I
' I
I
1
Cam switch
"Reference
pulse inhibit"
closed
closed
Switch
"Reference
pulse inhibit"
open
.I
I
21