HEIDENHAIN TNC 150 B Mounting Instructions page 37

Contouring control
Hide thumbs Also See for TNC 150 B:
Table of Contents

Advertisement

Function
.
RPM-range
for max. 8 gear
ratios with
S-analogue
voltage
output
Gear ratio
,O
1
2
3
4
5
6
7
Parameter
No.
78
79
80
81
82
83
84
85
-
I
I
(
Possible
Selected
entry wakes
entry values
3 - 9 000.000 rpm
With these parameters, the definition
of the gear stage is via the output of an S-analogue voltage. The highest
possible rpm (with S-override 100 %) is programmed for each gear stage. The gear stage with the lowest possible
rpm is programmed with parameter 78 etc. If less than 8 gear stages are programmed, the unused parameters
for gear stages are programmed with "0".
All parameters for gear stages are to be programmed with "0" if operation is with coded rpm output.
S-analogue voltage with
S-override 100 %
86
0 - 9.999 Volts
Parameter No. 86 sets the analogue voltage output for gear stages with override = 100 %.
S-analogue voltage with
S-override at max. output
voltage
Parameter No. 87 sets the absolr
?r---jmT
te max. of the analogue voltage output for the gear stages.
f-imitation
of
S-override
maximum
minimum
88
89
o-
150%
With these pa.rameters, the limitation
for the S-override potentiometer
is programmed (No. 88 maximum,
No. 89 minimum). After
reaching the programmed limitation
- either max. or min., the S-analogue voltage
remains constant.
Minimum for feed rate
override with tapping
Maximum for feed rate
override with tapping
182
183
With these parameters, the range of the feed rate override for the tapping cycle can be limited.