Bipolai
outputs
(PL 110 B: A25 to A30 and A57 to A62)
Nominal
voltage:
15 V
(measured
between
two bipolar
outputs,
with
one output
is switched
to signal "1"
and the other to signal "0")
Nominal
current:
300 mA
Voltage
range with
nominal
current:
14.6 V to 15.5 V
Max. output
current
1.2 A for 1 minute
Current
limitation
range: 1.35 A to 1.6 A
Permissible
load: Resistance
load;
inductive
load only with
quenching
diode parallel to inductivity
max. switching
frequency:
50 Hz
Please note:
Bipolar
PLC-outputs
may not be switched
in parallel.
When using the bipolar
outputs
as binary
output
signals:
Voltage
for signal "1":
,~14.2
V
Voltage for signal "0":
d
3.0 V
Nominal
current:
300 mA
Max. output
current
1.2 A for 1 minute
Output
current
supervision
Supervision
of output
currents
of all bipolar
outputs.
Outpui
J3/11
provides
signal "1"
if the sum of the out-
put currents
of all bipolar
outputs
is 70.8
A to 0.9 A
Nominal
voltage:
24 V, -
Max. output
current:
55 mA to 65 mA
Max. difference
to supply
voltage:
~1.5 V
2.3
Transducers
for TNC 150
23.1
Transducers
for TNC 150 B / TNC 150 Q
The TNC 150 controls
the actual position
with
a digital step of 0.001 mm and subdivides
the grating
period
of the transducers
by 20 x or 10 x. Incremental
linear transducers
with
a 20 urn or 10 urn grating
pitch such as
.LS 107 (measuring
lengths 240 mm to 3040 mm)
.LS 703 (measuring
lengths
170 mm to 3040 mm)
.LS 903 (measuring
lengths
70 mm to 1240 mm)
.LID 300,310
should
therefore
be used.
If accuracy
requirements
are permitting,
indirect
measuring
:;ystems e.g. rotary
encoders
type ROD 450 or
ROD 456 may be connected
to the drive spindles.
The requj-ed
number
of lines for the encoder
is calculated
as follows:
Line number
/ rev. = 50 x lead screw
pitch (in mm) with
20 x evaluation
(MP 12 - 15)
Line number
/ rev. = 100 x lead screw
pitch (in mm) with
10 x evaluation
(MP 12 - 15)
For angle measurement
(with
axis IV) rotary
encoder
types
?OD 250 and ROD 700 with
18.000 or
36.000
lines are available.
The cable length between
transducer
and TNC 150 must no1 exceed 20 m.