Installation & Set-Up For Mig Welding; 200C Installation For Mig/Mag Process - Linde BOC RAPTOR 250R MIG Operating Manual

Table of Contents

Advertisement

16
BOC RAPTOR 200C & 250R MIG Operating manual
6.0
Installation & Set-up for MIG welding
Installation for MIG/MAG process
A
6.1

200C Installation for MIG/MAG process

1 Connect the gas hose to the regulator and the rear of the
machine. Select correct shielding gas for the application.
2 Insert the earth return lead connection into the front panel.
3 Fit the wire spool to the machine. Select correct welding wire
for application.
4 Select the appropriate feed roller to suit the wire being used
- This machine comes complete with two types of wire feed
rollers
- V groove for use with solid carbon manganese and stainless
steels
- U groove for use with soft wires such as aluminium
5 Loosen the wire feed tension screws and insert the wire. Re fit
and tension rollers ensuring the wire is gripped sufficiently so
as not to slip but avoid over tightening as this can affect feed
quality and cause wire feed components to wear rapidly.
6 Fit and tighten the torch on the output connection [A]. Ensure
correct torch liner and contact tip are selected.
7 Select the correct polarity for the type of wire used as indicated
on the consumable packaging. This is achieved by swapping the
polarity terminal wires. For most solid wires the terminal should
be set as torch positive.
8 For torch positive, plug the short mechanical connector (link
plug) [B]on the front panel into the positive (+) terminal and the
work return lead [C] into the negative (-) terminal.
9 For torch negative, couple the short mechanical connector [B]
into the terminal marked negative (-), and the work return lead
[C] into the positive (+) terminal.
B
C
IMPORTANT
The 200C machine comes fitted with a 15A
rated single phase plug for compliance to
AS/NZ electrical regulations.